LTN
Appendix V—Standard Racked Assembly
wc_tx001216gb.fm
97
13.13 Routing the Coil Cord
Procedure
Follow the procedure below to route the coil cord.
1. At the base of the tower, wrap the coil cord around the tower twice, creating
loops of about 25 cm (10 in.) in diameter.
2. Loosen the connector
(CN)
. Pass the end of the coil cord through the connector
so that approximately 1 m (3 ft) of wires extend inside the Light Tower cabinet,
and re-tighten the connector
(CN)
.
3. Insert the red, black, brown, and orange wires from the coil cord into one of the
supplied looms. Pass this loom through the ballast bracket on the right side of
the machine
(R)
.
4. Insert the yellow, blue, white, purple, and green wires from the coil cord into the
second loom. Pass this loom through the ballast bracket on the left side of the
machine
(L)
.
wc_gr006536
CN
R
L