13.14 Wiring the Ballasts and Terminal Strips
Procedure
Follow the procedure below to wire the ballasts and terminal strips.
1. Remove the two ballast covers
(BC)
from the left and right sides of the Light
Tower.
2. Connect the green wire from the coil cord to the hexagonal grounding screw
(G)
.
3. Locate the four capacitors as shown below.
4. Connect four wires from the coil cord to the capacitors as follows:
5. Connect the remaining wires to terminal strips “A” and “B” according to the
diagram and tables on the next page. Torque all screws to 2.25 Nm (20 in.lbs.).
6. When all wires are connected to terminal strips “A” and “B,” re-install the ballast
covers. Torque the ballast cover mounting screws to 5.0 Nm (3.5 ft.lbs.).
Capacitor
Wire from coil cord
1
Red
2
Black
3
Yellow
4
Blue
wc_gr006537
G
BC
1
2
3
4
wc_gr006570
Содержание LTN 6L
Страница 1: ...0171883en 007 1110 0 1 7 1 8 8 3 E N Operator s Manual Light Tower LTN 6L 60 Hz ...
Страница 17: ...LTN 6L Labels wc_si000381gb fm 17 wc_gr007037 R S U V L H F B N J M D Y FF AA AA DD BB GG EE CC BB HH JJ ...
Страница 37: ...LTN 6L Operation wc_tx000766gb fm 37 o ...
Страница 69: ...LTN Appendix I Assembly Instructions wc_tx001218gb fm 69 Illustrations D wc_gr006517 ...