FUE 6
Technical data
29
12.2
Notes regarding class rating and protection class
Class rating
The class rating according to DIN EN 61140 specifies the safety measures for
electrical equipment to avoid electrocution. There are four class ratings:
Protection class IP
The protection class according to DIN EN 60529 indicates the suitability of elec-
trical equipment for use in certain ambient conditions as well as the protection
against risks.
The protection class is specified by an IP code according to DIN EN 60529.
Class rating
Meaning
0
No special protection apart from the basic insulation.
No grounded conductor.
Plug connection without grounded conductor contact.
I
Connection of all conductive housing components to the
grounded conductor.
Plug connection with grounded conductor contact.
II
Reinforced or double insulation (protective insulation).
No connection to the grounded conductor.
Plug connection without grounded conductor contact.
III
Equipment is operated on protective low voltage
(< 50 V).
Connection to the grounded conductor is not necessary.
Plug connection without grounded conductor contact.
Code
Meaning
IP
Code letter
International Protection
4
1st code number for protection from contact and foreign bodies:
Protected against touch with a wire (diameter > 1 mm (0.04 in)).
Protected against granular foreign objects (diameter > 1 mm (0.04 in)).
4
2nd code number for protection from water and moisture:
Protected against spraying water from all directions.