wc_tx001903gb.fm
64
Operation
E 1100
Ignition
carryover
The ignition carryover state starts as soon as the flame is established.
During this state:
The fuel shut-off valve is open (energized).
Pressurized fuel atomizes at the burner nozzle.
The atomized fuel is ignited by the electrodes.
The electrodes stay powered for up to 10 seconds after flame is
sensed.
When the ignition carryover state has elapsed:
The ignition transformer is shut off.
The burner control enters the run state.
If the flame is lost during the ignition carryover state:
If the lockout time has not expired, the burner control returns to trial-
for-ignition state.
If the lockout time has expired, the burner control enters the recycle
mode.
Run
The run state starts and continues once the ignition carryover state has
elapsed. During this state:
The fuel shut-off valve is open (energized).
Pressurized fuel atomizes at the burner nozzle.
The flame is monitored by the cad cell.
When the setpoint is reached (call for heat satisfied), the burner control
enters the burner-motor-off delay state.
If the flame is lost during the run state:
The burner control enters the recycle mode.
Burner-motor-
off-delay
The burner-motor-off-delay state starts immediately after the setpoint is
reached, i.e., the call for heat has been satisfied. The time of this state
is 30 seconds. During this state:
The output contacts of the temperature controller open, interrupting
the circuit between terminals labeled “T”.
The fuel shut-off valve closes (de-energizes).
The burner motor runs until the burner-motor-off delay expires, then
the burner motor turns off.
The burner control returns to the idle mode.
If the cad cell detects flame during the burner-motor-off-delay state:
The burner control goes into the standby state.
State
Action or Function
Содержание E1100
Страница 19: ...E 1100 Safety Information wc_si000628gb fm 19 Notes...
Страница 20: ...Labels E 1100 20 wc_si000629gb fm 2 Labels 2 1 Label Locations wc_gr009588...
Страница 105: ...ghi_tx001153gb fm 105 E 1100 Maintenance...
Страница 122: ...Technical Data E 1100 122 wc_td000476gb fm 10 5 Dimensions cm in wc_gr008706...
Страница 133: ...wc_tx001673gb fm 133 Fuji Temperature Controller...
Страница 134: ...wc_tx001673gb fm 134 Fuji Temperature Controller...
Страница 147: ...E 1100 Schematics wc_tx001908gb fm 147 11 Schematics 11 1 E 1100 Composite Schematic ghi_gr005662...
Страница 151: ...E 1100 Schematics wc_tx001908gb fm 151 11 3 Burner System Circuit...
Страница 152: ...Schematics E 1100 152 wc_tx001908gb fm 11 4 Circulation System Circuit ghi_gr005662...
Страница 153: ...E 1100 Schematics wc_tx001908gb fm 153 11 5 Rewind System Circuit...
Страница 158: ...Schematics E 1100 158 wc_tx001908gb fm 11 10 Genset DC Wiring Diagram...
Страница 160: ......
Страница 161: ......