wc_tx001903gb.fm
61
E 1100
Operation
4.24
Resetting a Low HTF Fault
Requirements
Genuine Wacker Neuson Heat Transfer Fluid, or
Dowfrost HD 50 Heat Transfer Fluid
NOTICE:
Use only factory-recommended Heat Transfer Fluid (HTF). Failure to do
so may damage the machine.
Important
The procedure for routine filling of the HTF reservoir differs slightly from that when
a low level fault is encountered. If you are filling the reservoir during normal
operation, see topic
Filling the HTF Reservoir
.
Background
The HTF reservoir includes a sensor that will trigger the low-level shut-down device
to stop the machine’s function if the HTF falls below the minimum operational
capacity. During a low HTF level condition the following occurs:
The control panel low level fault light illuminates
Power is cut to the burner
Power is cut to the pumps
The low-level shut-down device “LOW WATER” light illuminates
Resetting a
low HTF fault
Follow the procedure below to reset a low HTF fault.
1. Move the burner switch to the OFF position.
2. Move the pump switch to the OFF position.
3. Clean the fill hose.
4. Move valve #2 to the maintenance position (valve handle pointing up).
5. Place the open end of the fill hose
(a)
into a container full of HTF.
This procedure continues on the next page.
wc_gr008699
a
2
Содержание E1100
Страница 19: ...E 1100 Safety Information wc_si000628gb fm 19 Notes...
Страница 20: ...Labels E 1100 20 wc_si000629gb fm 2 Labels 2 1 Label Locations wc_gr009588...
Страница 105: ...ghi_tx001153gb fm 105 E 1100 Maintenance...
Страница 122: ...Technical Data E 1100 122 wc_td000476gb fm 10 5 Dimensions cm in wc_gr008706...
Страница 133: ...wc_tx001673gb fm 133 Fuji Temperature Controller...
Страница 134: ...wc_tx001673gb fm 134 Fuji Temperature Controller...
Страница 147: ...E 1100 Schematics wc_tx001908gb fm 147 11 Schematics 11 1 E 1100 Composite Schematic ghi_gr005662...
Страница 151: ...E 1100 Schematics wc_tx001908gb fm 151 11 3 Burner System Circuit...
Страница 152: ...Schematics E 1100 152 wc_tx001908gb fm 11 4 Circulation System Circuit ghi_gr005662...
Страница 153: ...E 1100 Schematics wc_tx001908gb fm 153 11 5 Rewind System Circuit...
Страница 158: ...Schematics E 1100 158 wc_tx001908gb fm 11 10 Genset DC Wiring Diagram...
Страница 160: ......
Страница 161: ......