POS-123-P-PFN
5.5.4
OFFSET (Zero correction)
Command
Parameters
Unit
Group
OFFSET
x
x= -
4000… 4000
0.01 %
IO_CONFIG
This parameter is entered in 0.01% units.
The offset value is added to the output value. Valve zero offsets can be compensated with this parameter.
5.5.5
SIGNAL:U (Polarity of the output signal)
Command
Parameter
Unit
Group
SIGNAL:U x
x=
+|-
-
IO_CONFIG
This command is used to switch the polarity of the control signal.
5.6 Power stage
5.6.1
CURRENT (Rated output current)
Command
Parameters
Unit
Group
CURRENT
x
x= 500… 2600
mA
POWERSTAGE
The nominal output current is set. Dither and also MIN/MAX always refer to this current range.