Page 19 of 53
POS-123-P-PFN
5 Parameter
5.1 Parameter overview
Group
Command
Default
Unit
Description
MODE
SYSTEM -
Visible parameter group
Basic parameters
LG
EN -
Selecting language
SENS
ON -
Malfunction monitoring
PASSFB
0 -
Password for fieldbus parameterisation
EOUT
0 0.01 %
Output signal if no ready
3330
-3330
0.01 %
0.01 %
Output signal in manual mode
POSWIN:S
POSWIN:D
200
200
µm
µm
Ranges of the in-position monitoring
Input signal adaption
SYS_RANGE
100 mm
Axis working stroke
Sensor scaling
SIGNAL:X
U0-10 -
Type of input signal
N_RANGE:X
100 mm
Nominal pressure of the sensor
OFFSET:X
0 µm
Sensor Offset
Position controller
VRAMP
200 ms
External speed ramp time
VMODE
SDD -
Method of positioning
Profile generator NC
ACCEL
250 mm/s²
Acceleration in NC mode
VMAX
50 mm/s
Maximum speed in NC mode
V0:A
V0:B
V0:RES
10
10
1
1/s
1/s
-
Closed loop gain in NC mode
Switchover of the resolution.
Control parameter SDD
A:A
A:B
100
100
ms
ms
Acceleration (ramp times) in SDD mode
25
25
10
mm
mm
mm
Deceleration stroke in SDD mode
Common
PT1
1 ms
PT1 time constant
SQRT1 -
Control characteristics