VWR avantor 710-2126 Скачать руководство пользователя страница 22

 

 

22     

vwr.com

 I Instruction manual VWR

®

 Media Pump 

 

 

 

Make sure that the rollers of the main pump and pump extension are NOT aligned but staggered in 

relation to each other:

 

  

If WRONG, separate the pump from the pump extension by pushing the tab (see Picture 1). Move aside the rollers 

wheel a little bit and clip the pump and the pump extension together again. 
Replace the booster kit on the pump holder. 

User replaceable accessories and spare parts 

 

Description 

Quantity 

Cat. No. 

Foot pedal 

710-2093 

Set of silicone tubes for pump part (20 cm each). inner ø  4.8 mm for VWR Media Pump

 

710-2141

 

Stand to store independently broth bags

 

710-2109

 

Trocar for broth bags

 

710-2111

 

Autoclavable  0.2 µm PTFE filter for GL45 cap

 

710-2099

 

Set of stainless steel nozzles for tubing Ø 6,4 mm

 

 

710-2112

 

Set of tube weights

 

710-2114

 

Set of stainless steel nozzles for tubing Ø 3,2 mm

 

710-2113

 

Dispensing control with handy gun including electronic start button for VWR Media Pump

 

710-2127

 

For dispensing in container (maximum height 41 cm )  for VWR Media Pump

 

710-2128

 

Set of silicone tubings inner ø 1.6 mm + GL45 screw cap + tube  inox  filter for 

VWR Media Pump

 

710-2129

 

Set of silicone tubings inner ø 3.2 mm + GL45 screw cap + tube  inox  filter for 

VWR Media Pump

 

710-2130

 

Set of silicone tubings inner ø 4.8 mm + GL45 screw cap + tube  inox  filter for 

VWR Media Pump

 

710-2131

 

Set of silicone tubings inner ø 6.4 mm + GL45 screw cap + tube  inox  filter for 

VWR Media Pump

 

710-2132

 

Set of silicone tubings inner ø 8 mm + GL45 screw cap + tube  inox  filter for 

VWR Media Pump

 

710-2133

 

Set of dispensing tubings inner ø 1.6 mm with plastic connectors for VWR Media Pump

 

710-2134

 

Set of dispensing tubings inner ø 3.2 mm with plastic connectors for VWR Media Pump

 

710-2135

 

Set of dispensing tubings inner ø 4.8 mm with plastic connectors for VWR Media Pump

 

710-2136

 

Set of dispensing tubings inner ø 6.4 mm with plastic connectors for VWR Media Pump

 

710-2137

 

Set of dispensing tubings inner ø 8 mm with plastic connectors for VWR Media Pump

 

710-2138

 

Set of silicone tubes for pump part (20 cm each). inner ø  1.6 mm for VWR Media Pump

 

710-2139

 

Set of silicone tubings for pump part (20 cm each)

 

710-2100

 

Set of silicone tubes for pump part (20 cm each). inner ø  3.2 mm for VWR Media Pump 

710-2105 

Set of silicone tubes for pump part (20 cm each). inner ø  8 mm for VWR Media Pump

 

710-2142

 

 

Technical service

 

Web Resources 

Visit the VWR website at 

www.vwr.com 

for: 

• Complete technical service contact information 
• Access to the VWR Online Catalogue, and information about accessories and related products

 

• Additional product information and special offers

 

CORRECT 

INCORRECT 

Содержание avantor 710-2126

Страница 1: ...Instruction manual VWR Media Pump EU cat no 710 2126 ___ Version 01 Issue 06 2021 For manuals in other languages please visit vwr com...

Страница 2: ...nufacturer Europe VWR International bv Researchpark Haasrode 2020 Geldenaaksebaan 464 B 3001 Leuven 3216385011 http be vwr com UK Importer VWR International Ltd Hunter Boulevard Magna Park Lutterworth...

Страница 3: ...ttons and Switches 7 Operational keys 9 Getting Started 9 Important Guidelines 10 General settings 11 Operation 12 Calibration 15 Troubleshooting 20 Appendix 20 Repair and maintenance of Media Pump 21...

Страница 4: ...ed Media Pump can be used with lab temperature from 5 to 30 C Media Pump is in compliance with ISO 7218 and FDA BAM standards 2 precision can be achieved in many applications Safety Information Avoidi...

Страница 5: ...the tube into the peristaltic pump from front to back Be careful to center it to avoid pinching the tubing when closing the pump BE CAREFUL carefully read the tubing installation guide provided When t...

Страница 6: ...hell designed to last long Product Specifications Dose volume 50 L to 99 L Dispensing modes Continuous Dose Multi dose Multi dose pause Adjustable from 0 1 to 99 9 s Watson Marlow pump Single pump hea...

Страница 7: ...posed of a screen a rotating button and a few other buttons Information and menus appear on screen The rotating button at the right side of the screen is the main control of the Media Pump it allows y...

Страница 8: ...n Example of the main menu when the Media Pump is turned on The on screen menu is hierarchical the user can when choosing an option in the menu go to another menu called sub menu For example the optio...

Страница 9: ...user controls by hand or by foot the starting moment of the pump for the first dose The pump automatically stops when the programmed volume is dispensed Then it automatically dispenses again after a p...

Страница 10: ...apted for dispensing of little volumes On the side of the Media Pump is engraved 1 diagram It shows the precision that you can get according to your volume and the inner diameter of the tubing Example...

Страница 11: ...on of the pump The arrow displayed in front of F L O W D I R E C T I O N indicates the direction towards which goes the pump and consequently the direction in which the tubing must be placed If the ar...

Страница 12: ...menu choose the option MODIFY PROGRAMS On the screen will appear the list of the programs already created If you scroll the list at the end will appear a list of standard names program 5 program 6 et...

Страница 13: ...g Then turn the button to modify the character under the cursor Typographic characters scroll numbers first and then alphabetic letters and punctuation characters Turn the button until the character a...

Страница 14: ...ntal mode Launch the program When the pump is working the speed is displayed on screen and you can modify with the rotating button The last chosen figure is memorized in the program Inner diameter of...

Страница 15: ...n an optimal precision calibration is recommended Principle of operations The operation consists in pouring a fixed volume of liquid in conditions closest to real conditions to measure it and then ent...

Страница 16: ...k possibly by weighing the volume of the poured liquid Calculation of accuracy The accuracy depends on 2 things tubing inner diameter dispensed volume during calibration Tubing inner diameter The tubi...

Страница 17: ...d an operation You can temporarily suspend the operation by 3 ways by pressing the START STOP button on the rotating button or on the esc button You can start the dispensing again by pressing the STAR...

Страница 18: ...y pressing the START STOP button At the end of all dispensing the screen displays nothing special but that the 2 progression indicators are complete The Media Pump makes a little bip sound if the opti...

Страница 19: ...the BASIC PUMPING function in the main menu To do so select the option in the main menu and then press the START STOP button or on the rotating button and then press the same button again Stop the pu...

Страница 20: ...the density in the calibration process see chapter Calibration The pump has been opened Calibrate after each opening of the pump Appendix Using the handy gun ref 710 2127 For highly precise work you c...

Страница 21: ...the dust and dirt with a soft cloth Once a week grease the pump head with a universal multi purpose grease to the friction areas see diagram below to prevent premature wearing Signs of wearing of pum...

Страница 22: ...r for VWR Media Pump 1 710 2130 Set of silicone tubings inner 4 8 mm GL45 screw cap tube weight inox nozzle filter for VWR Media Pump 1 710 2131 Set of silicone tubings inner 6 4 mm GL45 screw cap tub...

Страница 23: ...NTY OF MERCHANTABILITY Compliance with local laws and regulations The customer is responsible for applying for and obtaining the necessary regulatory approvals or other authorisations necessary to run...

Страница 24: ...R International Ltd VWR International Northern Ireland Ltd Orion Business Campus Northwest Business Park Ballycoolin Dublin 15 Tel 353 01 88 22 222 Email sales ie vwr com Italy VWR International S r l...

Отзывы: