VWR avantor 710-2126 Скачать руководство пользователя страница 18

 

 

18     

vwr.com

 I Instruction manual VWR

®

 Media Pump 

 

 

Example: 

 

 At the end of dispensing, the screen displays “DISTRIBUTION PERFORMED”. You can then start the dispensing of 
another dose by pressing “START/STOP” or on the rotating button or using the gun or the foot pedal. 

During the dispensing and at the end of each dose, the screen displays a count of the number of doses. 
 

Example, after 10 doses: 
 

 

 

 

Press “esc.” to quit the program. 

Dispensing in “multi-doses” mode 

During dispensing the Media Pump displays a reminder of the name of the program, the dose volume, the number 

of doses of the program and the direction and speed of the pump. 
It also displays two progress indicators: 

• 

on the number of doses  

• 

on the dose in dispensing  

Example: 

 

 
Note: during dispensing and during the waiting delay between 2 doses, you can temporarily suspend the 
operations by pressing the “START/STOP“ button. 

At the end of all dispensing, the screen displays nothing special but that the 2 progression indicators are 

complete. The Media Pump makes a little "bip" sound if the option “SON” is activated (see chapter “3.6.3 Sound”). 
You can then start the dispensing of another series of doses by pressing “START/STOP” or on the rotating button 

or by using the gun or the pedal. If not, press “esc.” to quit the program.  

Dispensing in continuous mode  

During dispensing, the Media Pump displays the name of the program, the inner diameter of the tubing and the 

direction and rotation speed. It also displays the flow in milliliters per minute, the large number at the center of 
the screen.  

 

 

 

    t u b e   9 m l  
 
    D I S T R I B U T I O N   1 0  
        P E R F O R M E D  
 
 
  9 . 0 0 m l       3 0 0   r p m  

    m u l t i   9 m l  

 

    D O S E             1 0 / 4 1  

 
D O S E   I N   P R O G R E S S  

 

  9 . 0 0 m l       3 0 0   r p m  

9 doses have already been 

dispensed. The 10

th

 one is being 

dispensed… 

Total number of doses  

    t u b e   9 m l  
 
    D I S T R I B U T I O N   1  
        I N   P R O G R E S S  
 
 
  9 . 0 0 m l       3 0 0   r p m  

Содержание avantor 710-2126

Страница 1: ...Instruction manual VWR Media Pump EU cat no 710 2126 ___ Version 01 Issue 06 2021 For manuals in other languages please visit vwr com...

Страница 2: ...nufacturer Europe VWR International bv Researchpark Haasrode 2020 Geldenaaksebaan 464 B 3001 Leuven 3216385011 http be vwr com UK Importer VWR International Ltd Hunter Boulevard Magna Park Lutterworth...

Страница 3: ...ttons and Switches 7 Operational keys 9 Getting Started 9 Important Guidelines 10 General settings 11 Operation 12 Calibration 15 Troubleshooting 20 Appendix 20 Repair and maintenance of Media Pump 21...

Страница 4: ...ed Media Pump can be used with lab temperature from 5 to 30 C Media Pump is in compliance with ISO 7218 and FDA BAM standards 2 precision can be achieved in many applications Safety Information Avoidi...

Страница 5: ...the tube into the peristaltic pump from front to back Be careful to center it to avoid pinching the tubing when closing the pump BE CAREFUL carefully read the tubing installation guide provided When t...

Страница 6: ...hell designed to last long Product Specifications Dose volume 50 L to 99 L Dispensing modes Continuous Dose Multi dose Multi dose pause Adjustable from 0 1 to 99 9 s Watson Marlow pump Single pump hea...

Страница 7: ...posed of a screen a rotating button and a few other buttons Information and menus appear on screen The rotating button at the right side of the screen is the main control of the Media Pump it allows y...

Страница 8: ...n Example of the main menu when the Media Pump is turned on The on screen menu is hierarchical the user can when choosing an option in the menu go to another menu called sub menu For example the optio...

Страница 9: ...user controls by hand or by foot the starting moment of the pump for the first dose The pump automatically stops when the programmed volume is dispensed Then it automatically dispenses again after a p...

Страница 10: ...apted for dispensing of little volumes On the side of the Media Pump is engraved 1 diagram It shows the precision that you can get according to your volume and the inner diameter of the tubing Example...

Страница 11: ...on of the pump The arrow displayed in front of F L O W D I R E C T I O N indicates the direction towards which goes the pump and consequently the direction in which the tubing must be placed If the ar...

Страница 12: ...menu choose the option MODIFY PROGRAMS On the screen will appear the list of the programs already created If you scroll the list at the end will appear a list of standard names program 5 program 6 et...

Страница 13: ...g Then turn the button to modify the character under the cursor Typographic characters scroll numbers first and then alphabetic letters and punctuation characters Turn the button until the character a...

Страница 14: ...ntal mode Launch the program When the pump is working the speed is displayed on screen and you can modify with the rotating button The last chosen figure is memorized in the program Inner diameter of...

Страница 15: ...n an optimal precision calibration is recommended Principle of operations The operation consists in pouring a fixed volume of liquid in conditions closest to real conditions to measure it and then ent...

Страница 16: ...k possibly by weighing the volume of the poured liquid Calculation of accuracy The accuracy depends on 2 things tubing inner diameter dispensed volume during calibration Tubing inner diameter The tubi...

Страница 17: ...d an operation You can temporarily suspend the operation by 3 ways by pressing the START STOP button on the rotating button or on the esc button You can start the dispensing again by pressing the STAR...

Страница 18: ...y pressing the START STOP button At the end of all dispensing the screen displays nothing special but that the 2 progression indicators are complete The Media Pump makes a little bip sound if the opti...

Страница 19: ...the BASIC PUMPING function in the main menu To do so select the option in the main menu and then press the START STOP button or on the rotating button and then press the same button again Stop the pu...

Страница 20: ...the density in the calibration process see chapter Calibration The pump has been opened Calibrate after each opening of the pump Appendix Using the handy gun ref 710 2127 For highly precise work you c...

Страница 21: ...the dust and dirt with a soft cloth Once a week grease the pump head with a universal multi purpose grease to the friction areas see diagram below to prevent premature wearing Signs of wearing of pum...

Страница 22: ...r for VWR Media Pump 1 710 2130 Set of silicone tubings inner 4 8 mm GL45 screw cap tube weight inox nozzle filter for VWR Media Pump 1 710 2131 Set of silicone tubings inner 6 4 mm GL45 screw cap tub...

Страница 23: ...NTY OF MERCHANTABILITY Compliance with local laws and regulations The customer is responsible for applying for and obtaining the necessary regulatory approvals or other authorisations necessary to run...

Страница 24: ...R International Ltd VWR International Northern Ireland Ltd Orion Business Campus Northwest Business Park Ballycoolin Dublin 15 Tel 353 01 88 22 222 Email sales ie vwr com Italy VWR International S r l...

Отзывы: