 Detailed Descriptions: 

Wire Harness Colors and Func�ons

 Input / Output Connector (22-pin connector) 

See page 33 for the full system diagram.

 These wires are listed in order of their placement in the harness connector.

9. BLACK/YELLOW – Pulse During Crank Output (-) (NOC 3)

At its default setting, the BLACK/YELLOW wire supplies a Ground (-) pulse when the engine cranks during remote start.

Note: 

This wire is programmable. 

Refer to NOC Programming on page 17.

21

22

19

20

17

18

15

16

13

14

11

12

9

10

7

8

5

6

3

4

1

2

1. ORANGE – Starter Kill Output (-)

The ORANGE wire supplies Ground (-) when the alarm is armed and when the remote start is ON. 

2. LIGHT GREEN – Trunk / Hatch Input (-) (PIC1)

The LIGHT GREEN wire connects a device or switch that, when triggered, supplies a Ground (-) output. If the system is 

armed, this input will trigger the alarm. 

Note: 

This wire is programmable. 

Refer to PIC Programming on page 20.

3. GRAY/BLACK – Hood Input (-) (PIC2)

The GRAY/BLACK wire connects to the vehicle's hood switch, or an installed switch that registers Ground (-) when 

triggered. 

Note: 

This wire is programmable. 

Refer to PIC Programming on page 20.

Verification: 

The vehicle hood switch wire registers Ground (-) when the hood is opened.

4. GREEN/ORANGE – Tach Input

The GREEN/ORANGE wire connects to the vehicle’s tach wire at the nega�ve side of the igni�on coil or fuel injector to 

control engine crank during remote start.

Verification: 

• 

Using a voltmeter set to AC volts, connect the voltmeter’s posi�ve lead to a constant vehicle   

 

 

12-Volts (+) source and the nega�ve lead to the wire to be tested.  

• 

Start the engine and have a partner slowly press the gas pedal while the transmission is in Park. If the voltage  

increases as the RPM increases, this is the proper tach wire. 

5. LIGHT BLUE – Remote Start Status Output (-) (NOC 1)

The LIGHT BLUE wire supplies Ground (-) as soon as the remote starter is ac�vated and remains ac�ve un�l (4) seconds 

a�er remote start run �me has ended. This wire is most commonly used to ac�vate data integra�on modules.

Note: 

This wire is programmable. 

Refer to NOC Programming on page 11.

6. PURPLE/BROWN – Door Trigger Input (-/+)

The PURPLE/BROWN wire connects to the vehicle's door trigger wire. This wire will detect 12-Volt (+) or Ground (-) input.

Verification: 

The vehicle door trigger wire registers 12-Volt (+) or Ground (-) when a door is opened and opposite when 

closed.

Note: 

Programming is required if the door trigger wire registers 12-Volt (+). 

Refer to Feature Programming on page 9.

7. GREEN/WHITE – Dome Light Output (-) (NOC 2)

The GREEN/WHITE wire supplies Ground (-) when Unlock is ac�vated from the Remote Control. This output will 

automa�cally turn off a�er 30 seconds. 

Note: 

This wire is programmable. 

Refer to NOC Programming on page 17.

8. GREEN/YELLOW – Diesel Glow Plug Input (+) (PIC3)

The GREEN/YELLOW wire connect to the vehicle's Diesel Glow Plug detec�on wire.

Verification:

 This wire will register as 12-Volt (+) while the Diesel Wait to Start Light is illuminated.

Note: 

This wire is programmable. 

Refer to PIC Programming on page 20.

Содержание APS787Z

Страница 1: ...28 Alarm Override Procedures 29 Wiring Diagrams 29 Door Lock Connec ons 32 Starter Kill Relay 33 Full System Connections Thank you for trus ng Pres ge products If you are a consumer please note Profe...

Страница 2: ...he vehicle is in igni on mode AND during engine crank Note This wire can be programmed to perform a different func on by changing its op ons Refer to Bank 3 Feature 7 on page 13 6 RED WHITE 12 Volt In...

Страница 3: ...p ons Refer to Bank 2 Feature 14 on page 9 4 BLACK Ground Input The BLACK wire connects to a reliable vehicle ground source to power the system Verification The vehicle ground source wire registers gr...

Страница 4: ...rification Using a voltmeter set to AC volts connect the voltmeter s posi ve lead to a constant vehicle 12 Volts source and the nega ve lead to the wire to be tested Start the engine and have a partne...

Страница 5: ...OC 6 At its default setting the BLACK LIGHT GREEN wire supplies a Ground pulse when the system is armed and when the vehicle has been successfully started using remote start It is typically used to re...

Страница 6: ...changing its op ons Refer to Bank 2 Feature 14 on page 9 and NOC Programming on page 17 20 RED Door Lock NOC 10 The RED wire supplies Ground when the Lock func on is ac vated from the remote control o...

Страница 7: ...DBI Port The 4 pin Data Bus Interface enables a FlashLogic door lock or transponder interface to connect to and communicate with the vehicle data bus The combined system saves installa on me as many f...

Страница 8: ...wo 2 2 Way remote controls During normal opera on the Programmed Transmitter Notification PTN function indicates how many remote controls are programmed by flashing the LED a certain number of mes whe...

Страница 9: ...milliseconds Option 2 Lock and Unlock outputs will pulse for 3 5 seconds Option 3 Lock output will pulse for 500ms Unlock output will pulse twice 500ms each Option 4 Lock output will pulse twice 500m...

Страница 10: ...output to activate for a set time Setting Choices Option 1 Output pulses for 16 milliseconds Option 2 Output pulses for 30 milliseconds Option 3 Output pulses for 40 milliseconds Option 4 Output puls...

Страница 11: ...2 Door Trigger detec on is set for 12 Volt Feature 11 Silent ChoiceTM Func on Set audible beeps on or off when arming and disarming the system Setting Choices Option 1 Pressing Lock or Unlock at any t...

Страница 12: ...Option 6 120 seconds System will wait 120 seconds before monitoring the door trigger input Security Control Bank 2 Cont See page 23 for Programming Instruc on Detailed Descriptions Setup Op ons Featu...

Страница 13: ...ulse 350ms 500ms 800ms Same As Bank 2 F1 20 Addi onal Unlock Pulse No Pulse IGN ACC GWR IGN ACC GWR PASD Features Feature Bank 3 Op ons Feature 1 Defrost Output Duration Func on Set the Defrost output...

Страница 14: ...s informa on through an a ached data bus interface Option 4 No sensing assumes vehicle has started based on setting in Bank 3 Features 11 14 Feature 9 Accessory Output Function Purple Func on Set the...

Страница 15: ...mperature drops below 0 F Option 5 Vehicle will start when temperature drops below 4 F Option 6 Vehicle will start when temperature drops below 14 F Note Requires Ac va on with Remote Feature 14 Crank...

Страница 16: ...Ground While Running and Pulse After Shutdown wires upon unlock Feature 19 Factory Disarm Output Function BLACK BLUE Func on Set the functionality of the programmable output Setting Choices Option 1...

Страница 17: ...nlock This op on supplies a pulse when the Unlock func on is ac vated from the remote control or system 2nd Door Unlock This op on supplies a pulse when the Unlock func on is ac vated from the remote...

Страница 18: ...Descriptions Setup Op ons Ch 5 AUX This op on will supply an output when the AUX 2 func on is pressed on the remote control or CarLink system See page 19 for AUX Output Op ons Ch 6 AUX This op on wil...

Страница 19: ...rom the remote or CarLink System 10 Second Pulse This op on supplies a ten 10 second pulse each me the AUX Ch is ac vated from the remote or CarLink System 20 Second Pulse This op on supplies a twenty...

Страница 20: ...the door is open If using an LCD RF kit this input will display the Door icon when the Alarm is triggered Pre Warn Shock Trigger Input This op on will be used to add addi onal security sensors to the...

Страница 21: ...rs Hood or Trunk Igni on ON Parking Brake OFF If ready mode is canceled the vehicle will not remote start The user must repeat Steps 1 5 above to ac vate Ready Mode Easy Entry Mode Easy Entry Mode all...

Страница 22: ...ring will control the basic system func ons See Owner s Guide for more detailed informa on Five Bu on Remotes 1 Way 2 Way LED Button Action Function Press 1x Lock Hold 3 Seconds Panic ON OFF Press 1x...

Страница 23: ...dure 1 Turn the igni on ON 2 Press and release the valet bu on three 3 mes 3 The system will beep one 1 me indica ng you have accessed Bank 1 4 Each cycle of the Igni on OFF ON will advance to the nex...

Страница 24: ...ty Options See pages 9 12 for detailed descrip ons 1 Chirp 2 Chirp 3 Chirp 4 Chirp 5 Chirp 6 Chirp 1 Lock Unlock Func on 500ms 3 5sec 500ms L DBL UL DBL L 500ms UL DBL L DBL UL 500ms L 350ms UL 2 Igni...

Страница 25: ...earned If the parking lights do not flash locate another tach source and repeat steps 1 4 above Note Programming tach signal via OEM or Telema cs control is only available on Firmware v1 47 or Higher...

Страница 26: ...key Turbo Timer This model is equipped with a Turbo Timer This feature will automa cally engage the remote start to keep the vehicle s engine running This will allow for the engine to properly cool do...

Страница 27: ...g Remote Start All Pres ge remote start system will provide parking light feedback to display remote start errors or shutdowns The vehicle parking lights will flash to display error or shutdown code 1...

Страница 28: ...N 4 Within ve 5 seconds Press the valet bu on one 1 me 5 Turn the vehicle igni on to OFF then ON to start the vehicle Custom Code Programming Procedure In this example the user has selected Custom Cod...

Страница 29: ...re ac vated Negative Trigger Door Locks Verification The vehicle wires register Ground when the Lock and Unlock switches are ac vated Lock Unlock Vehicle Door Lock Control Relays RED Lock Output GREEN...

Страница 30: ...itive Multiplex Door Locks Relays required Verification The vehicle wire registers variable 12V values when the Lock and Unlock switches are ac vated Please consult the vehicle speci c wire and loca o...

Страница 31: ...ted Aftermarket Actuators Relays and door lock actuators required Lock Unlock 87 87a 86 85 30 87 87a 86 85 30 Fused 12 Volt Battery Souce Fused 12 Volt Battery Souce RED Lock Output Green Unlock Outpu...

Страница 32: ...ck Reference Wiring Diagrams Starter Kill Anti Grind Relay Connections Starter Kill An Grind Relay Op onal L O C K A CC ON S T A R T CUT 87 87a 86 85 30 To Vehicle Ignition To ORANGE Starter Kill Anti...

Страница 33: ...va on Input PIC 5 11 Black Red Pulse A er Shutdown Output NOC 4 10 Orange Black Parking Brake Input PIC 4 9 Black Yellow Pulse During Crank Output NOC 3 8 Green Yellow Diesel Glow Plug Input PIC 3 7...

Отзывы: