background image

TM

INSTALLATION GUIDE

TM

FCC ID NOTICE

This device complies with Part 15 of the FCC rules. Operation is subject to the  following conditions:

1. This device may not cause harmful interference, and

2.This device must accept any interference received, including interference that may cause undesired operation.

CAUTION: Changes or modifications not expressly approved by the part responsible for compliance void the user’s authority to operate 

this devise.

www.ultrastarters.com

WARNING: NEVER USE AN AUTOMATIC TRANSMISSION 

STARTER IN A MANUAL TRANSMISSION VEHICLE!

REV.2011.7.22

80 SERIES

 

AUTOMATIC AND MANUAL TRANSMISSION MODELS*

*MUST USE M SERIES REMOTE STARTER!

 

Advanced Remote Starters & Vehicle Security Systems

Содержание 80 Series

Страница 1: ...ding interference that may cause undesired operation CAUTION Changes or modifications not expressly approved by the part responsible for compliance void the user s authority to operate this devise www...

Страница 2: ...9 Enter Program Mode System Reset Menu 1 2 3 4 Quick View SYSTEM WIRING DETAILS 10 14 Connector Views Wiring Description PROGRAM MENUS 15 23 Program Menu 1 Detailed Program Menu 2 Detailed Program Men...

Страница 3: ...TION INPUT CONNECT TO COIL INJECTOR BRAKE SWITCH INPUT 12VOLT WHEN BRAKE IS PRESSED HOOD PIN SWITCH GROUND WHEN HOOD IS OPENED PARK BRAKE INPUT M SERIES ONLY NEGATIVE DOOR INPUT WHEN DOOR OPENED Statu...

Страница 4: ...tem with the Fortin module connected to the data port to set the default to Fortin bypass module 1 2 3 4 SELECTABLE PARK LIGHT OUTPUT GROUND OUTPUT FOR ADDITIONAL SENSOR FULL TRIGGER FOR ALARM MODELS...

Страница 5: ...YPES THE DEFAULT SETTING IS FOR IDATALINK MODULES THE SECOND IS FOR FORTIN BYPASS MODULES IF THE BYPASS KIT IS A IDATA PRODUCT SIMPLY CONNECT TO THIS INPUT AND PROGRAM THE BYPASS MODULE AS PER THE INS...

Страница 6: ...E S Hybrid mode 1 This option requires a tach connection Once the vehicle starts the system will not monitor the tach input and stay running for 15 minutes Hybrid Mode 2 No Tach wire connection This s...

Страница 7: ...Program Switch to advance through the settings Confirmed by Park Lights Horn Siren chirps LED flashes 5 Press and hold the Program Switch to change the setting Confirmed by Park Lights Horn Siren chir...

Страница 8: ...S ENABLED 8 PASSIVE ARMING PASSIVE ST KILL FULL PASSIVE ARMING ENABLED PASSIVE SAFETY REARM ENABLED 9 ALARM SHOCK AUX SENSOR INTERNAL SHOCK DISABLED BOTH SENSORS DISABLED BOTH SENSORS ENABLED ACTIVE A...

Страница 9: ...4 Flashes 4 Chirps SYSTEM PROGRAMMING Menu 1 SYSTEM PROGRAMMING Menu 1 7 LEDS FLASH WHEN LOCKED ARMED LED FLASHES LEDS DO NOT FLASH WHEN LOCKED ARMED AUTO TACH TACHLESS SETTING LED FLASHES SETTING DES...

Страница 10: ...WN BLUE OUTPUT TO ACTIVATE IGNITION CIRCUIT WHITE SELECTABLE OUTPUT DEFAULT SECOND IGNITION RED 30A HIGH CURRENT 12VOLT INPUT YELLOW OUTPUT TO ACTIVATE START CIRCUIT RED 30A HIGH CURRENT 12VOLT INPUT...

Страница 11: ...iren on alarm models Programmable Connect to the negative horn wire on the vehicle for non alarm models Connect to wire on the siren Red or Brown for alarm models PIN 2 ORANGE Starter Kill Anti Grind...

Страница 12: ...PUT FOR FACTORYALARM DIS ARM NEGATIVE STARTER OUTPUT OUTPUT FOR TRUNK RELEASEACTIVATION NEGATIVEACCESSORYOUTPUT AUXILIARYOUTPUT 2 AUXILIARYOUTPUT 1 PROGRAMMABLE OUTPUT BRAKE SWITCH INPUT WHEN BRAKE IS...

Страница 13: ...pressed Manual Transmission Only Alarm Manual Transmission Only Connect to door pin for Passive Arming on non alarm models 8 BLACK WHT Park Brake Input Connect to the Park Brake wire Must be connecte...

Страница 14: ...hen the remote starter is activated this wire will switch to ground 2 BLACK Wire System Ground Connect this wire to the ground input on the bypass module 3 RED Wire 12volt Output LOW CURRENT Connect t...

Страница 15: ...EN Chirps 3 times 1 ENTER SHOCK SENSOR ADJUSTMENT MODE 2 ADJUSTING THE SHOCK SENSOR 3 EXITING SENSOR ADJUSTMENT MODE Note System will Arm or Disarm via silent arming prior to entering adjustment mode...

Страница 16: ...and goto step 6 Press Release BUTTON 4 on Remote to be Programmed for 2ND CAR OR PAD LOCK HORN will honk 1 time to confirm remote has been programmed If the HORN does not honk press button again HORN...

Страница 17: ...FF Press and release the Program Button Step 2 The system will respond with three park light flashes and the HORN optional will honk the same number of times as the events in memory Maximum four event...

Страница 18: ...12volts 87 86 85 87a 30 87 86 85 87a 30 Alarm and or Starter Module Door lock Output Blue Green Vehicle s Lock Unlock Switch USE SPDT 12v Relay POSITIVE DOOR LOCK LOW CURRENT 12volts 12volts 87 86 85...

Страница 19: ...dule Door lock Output Blue Green Unlock Resistor Lock Resistor Lock Unlock Switch USE SPDT 12v Relay REVERSE POLARITY DOOR LOCK SYSTEM 12volts 12volts Alarm and or Starter Module Door lock Output Blue...

Страница 20: ...horized dealer but have been registered please fill out the service request form at http www ultrastarters com wiring_diagrams html PRODUCT INFORMATION www ultrastarters com TECHNICAL SUPPORT support...

Отзывы: