De-stoning machine EP 1000
Version: 136401000_M0014772F_EN400/50D
Datum: 15.01.2021
- 26 / 40 -
6.2 List of materials
Pieces
Name
Item number Reference. Name oft he marker
1
VCD02 E-stop main switch 40A
120600001
-1Q1
Schneider Electric
1
Y-Dr-Switch
120101303
-1S1
Danninger GesmbH
1
ZB4-BS54 mushroom switch (E-stop) rt 40mm
160700005
-1S2
Schneider Electric
1
ZB4BZ102 bottom part 1NC installation
160700016
2
XCSPA592 Safety limit switch
121000520
-1S3, -1S4
Schneider Electric
1
LC1K1210V7 contactor 12A 5,5 kW 400 V
160300094
-1K1
Schneider Electric
1
GV2ME16 Motor prodection switch 9,0 - 14,0 A
160300051
-1F1
Schneider Electric
1
GVAE11 Hilfsschalter S + Ö Frontanbau
160300059
M9F22201 C60SP, 2P, 1A C LS-Switch
160300132
-1F2
Schneider Electric
1
E-Motor BG. 112 M 4-pol. B3 5,5 kW
105401130
-1M1
Moll - Motor
7
Fault and error analysis - machine/line components
7.1 General
WARNING AGAINST GENERAL DANGERS
In faults trouble shooting the safety instructions described in the chapter "Basic safety principles"
must be followed without fail!
INFORMATION!
When faults tables on the separate machine/line parts are not otherwise given, you can find further
information on the precise settings in the chapter "Controls and settings work before first starting
up/re-starting of line".
The precise replacement work is described in the chapter "Servicing and Repairs".
7.2
Fault and error analysis - machine/line components
Error/malfunction
Possible cause
Trouble shooting
Motor does not start up
Electrical defect
Check the electrical connections,
links, switches, drives and fuses
Main switch is defect
Control the mainswitch if it is defect change
it
Efficiency of the machine
is too low
Wrong direction of the motor rotation
Change the direction of the motor rotation
Stones in the mash
Wrong screen hole diameter
Change screen
Damaged stones
Distance between rotor and screen is
too low
Set rotor