Fuel.level.sender
Fresh.water.level.sender
Install.the.float.as.in.figure..Calculate.and.adjust.the.
length.of.the.float.arm.using.the.formula:..
R=H/1.64-18 mm.and.also.on.the.basis.of.the.mini-
mum.and.maximum.fuel.levels..
Example:.H=580.mm.(H/2=290.mm).
R=580/1.64-18.
R=353-18.
R=336.mm
Tighten.the.screw.and.cut.off.the.projecting.part.of.
the.float.arm.
IMPORTANT! It.is.very.important.that.the.float.is.
installed.on.the.correct.side.of.the.sensor.
NOTE!.Incorrect..
mounting.of.float
Calibration of fuel level
The.fuel.level.sender.is.calibrated.by.the.EVC.sys-
tem.tachometer/display.and.the.EVC.control.panel..
Please.refer.to.the.
Calibration and settings
.section.
in.this.manual.
Tighten.the.two.screws.on.the.sensor.securely..The.
minimum.fluid.level.must.not.be.lower.than.the.fluid.
exit.hole.
If.the.minimum.sensor.length.is.too.long,.you.can.cut.
it.to.a.suitable.length.
Fuel.level.sender
Fresh.water.level.sender
44
Installation.procedure,.engine.room.
EVC-C
Содержание EVC EC -C
Страница 1: ...EVCEC C Electronic Vessel Control D4 D6 D9 D12 D16 Installation 1 1 B E ...
Страница 2: ......
Страница 135: ...Notes 135 ...
Страница 136: ... References to Service Bulletins Group No Date Concerns 136 ...