Fuel multipoint calibration
When.FUEL.MULTIPOINT.CALIBRATION.is.select-
ed,.the.fuel.level.sender.is.calibrated.in.five.equally.
divided.steps;.20.%.full.(pos.1),.40.%.full.(pos.2),.60.
%.full.(pos.3),.80.%.full.(pos.4),.100.%.full.(pos.5)..
NOTE!.TO.perform.multpoint.calibration,.fuel.tank.
must.be.less.than.20%.full..If.calibration.skips.POS.1.
and.goes.directly.to.POS.2,.the.fuel.tank.contains.too.
much.fuel.and.the.calibration.will.not.be.correct..
1.. Activate.helm.station.by.pushing.the.ACTIVE.
STATION.BUTTON.
2... Select.SETTINGS.from.MAIN.MENU.by.turn-
ing.NAVIGATION.WHEEL..Push.NAVIGATION.
WHEEL.to.enter.SETTINGS.MENU.
3.. Select.FUEL.TANK.CALIBRATION.and.push.
NAVIGATION.WHEEL.
4.. Select.FUEL.MULTIPOINT.CALIBRATION.by.
turning.NAVIGATION.WHEEL..Push.NAVIGA-
TION.WHEEL.to.enter.FUEL.MULTIPOINT.
CALIBRATION.
5A.. If.the.number.after.
“POS”.in.the.dis-
play.is.flashing:
.
Fill.fuel.tank.with.
displayed.volume.
(POS.1).and.push.
NAVIGATION.
WHEEL..Add.fuel.
(do.not.reset.the.
pump).up.to.dis-
played.volume.for.
each.POS.until.the.
tank.is.filled.
6.. Push.BACK.BUT-
TON.to.return.to.
SETTINGS.MENU.
5B.. If.the.number.after.
“POS”.is.
not.flash-
ing:
.
Fill.fuel.tank.with.
displayed.volume.
(POS.1).and.push.
NAVIGATION.
WHEEL..Repeat.
procedure.for.each.
POS.until.the.tank.
is.filled..
6.. Push.BACK.BUT-
TON.to.return.to.
SETTINGS.MENU.
NOTE!.The.fuel.multipoint.calibration.procedure.differs.depending.on.EVC.software.release:.
99
EVC-C.
Calibration.and.settings
Содержание EVC EC -C
Страница 1: ...EVCEC C Electronic Vessel Control D4 D6 D9 D12 D16 Installation 1 1 B E ...
Страница 2: ......
Страница 135: ...Notes 135 ...
Страница 136: ... References to Service Bulletins Group No Date Concerns 136 ...
Страница 138: ...7745547 English 09 2007 ...