background image

  

•   Prior to and after each measurement, check your instrument and the measuring leads for 

damages. Never take any measurements if the protecting insulation is defective or the 

measuring instrument is damaged otherwise.

 

•   Be especially careful when dealing with voltages higher than 50 V/AC or 75 V/DC. Even at 

such voltages you can get a life-threatening electric shock if you come into contact with live 

electric wires.

 

•   The measuring instrument is suitable for use in dry or damp conditions. Avoid use in a damp 

or wet environment.

 

•   Always ensure that the test probes are perfectly clean. Dirty or even corroded test clips can 

lead to an incorrect measurement.

 

•   The measuring tips must only be touched at the handles provided for this purpose. Otherwise, 

there is danger of an electric shock.

 

•   Never exceed the highest permissible voltage values. If the stated values are exceeded, the 

product becomes damaged and a fatal hazard exists. (See chapter “Technical Data”).

 

•   The recovery time as specified in “Technical Data” must always be adhered to. Otherwise, the 

product could be damaged.

 

•  The voltage values specified are nominal voltages.

 

•  If the neutral wire (N) or the earth wire (PE) is interrupted, no reading is shown.

 

•   Use the measurement device only within the admissible ambient conditions (see chapter 

“Technical Data”).

 

•   Always attach the measuring tip cover if you are no longer using the device.

 

•   Store the measurement device in a dry, dust-free location when it is no longer used.

 

•   When using the voltage tester in the measurement category CAT III and CAT IV, it is recom-

mended to attach the plastic protective covers to the measuring tip to decrease the length of 

the free contact tips. This reduces the risk of possible short cut during testing.

 

•   CAT I   Measurement category I for measuring electrical and electronic devices that are 

not directly supplied with mains voltage (e.g. battery-operated devices, etc.).

 

•   CAT II   Measurement category II for measuring electrical and electronic devices that are 

directly supplied with mains voltage via a mains plug.

 

•   CAT III   Measurement category III for measuring building installations (e.g. mains sockets 

or sub-distributors).

 

•   CAT IV   Measurement category IV for measuring the source of low-voltage installations 

(e.g. main distribution, main transfer point of the utility company) and outdoors.

generAl BAttery instructions

•  Batteries should be kept out of the reach of children.
•   Do not leave batteries lying around in the open; there is a risk of them being swallowed by children or 

pets. If they are swallowed, consult a doctor immediately.

•   Leaking or damaged batteries can lead to caustic burning of the skin. Therefore, use suitable protective 

gloves.

•   Batteries must not be short-circuited, opened or thrown into fire. There is a risk of explosion.
•   Make sure that the polarity is correct when inserting the batteries (pay attention to plus/+ and minus/–).

Description of symBols

V Ac Dc

V/AC: Alternating voltage

V/DC: Direct voltage

6/12/24/50/120/230/400/600

Display of rated voltage range in volt (V)

Direct current positive potential DC

Direct current negative potential l DC

Electrical resistance in kilo-ohm

hz

Electrical frequency (Hertz)

 Warning - dangerous voltage (>50 V/AC, >120 V/DC) 

Function also possible with flat batteries or without batteries

Continuity test symbol

 

Symbol for continuity signal sound

Battery symbol for data of used battery

LOW BAT

Symbol for empty batteries

Conformity symbol, CE-approved

 Device and equipment for live works. Personal protective equipment 

required.

 

Protection class 2 (double or reinforced insulation/protective insulation)

G

 operAting instructions

VoltAge tester “Vc-62”

item no. 1313884

intenDeD use

The 2-pole voltage tester can be used to measure and display direct and alternating voltages in an electri-

cal low-voltage circuit. The product also has an acoustic and visual circuit indicator. Power is supplied by 

two batteries of type micro/AAA included in the delivery.
The voltage tester complies with the standard for two-pole voltage testers of 6 - 600 V CAT III 600 V 

according to EN 61243-3:2010 /EN 60529 as well as protection class IP64 (dust and spray water). The 

product is suitable for use in dry or damp conditions. Use during rain or other precipitation is not permitted. 

The voltage tester is designed for use by electrically skilled persons using personal protective equipment.
The measuring instrument must not be operated when the battery compartment is open.
Measuring under adverse ambient conditions such as dust and flammable gases, vapours or solvents is 

not permitted.
Always observe the safety instructions and all other information included in these operating instructions.
This product complies with the applicable national and European requirements. All names of companies 

and products are the trademarks of the respective owners. All rights reserved.

pAckAge contents

•  Voltage tester
•  2x batteries micro/AAA
•  2x protective plastic covers 
•  2x 4 mm adapters to screw onto the measuring sensors
•  Operating instructions

explAnAtion of symBols

 

 The lightning symbol in a triangle warns of electric shock danger or the impairment of the 

electrical safety of the appliance.

 

 An exclamation mark inside a triangle points out important instructions in the operating manual.

 

The arrow symbol indicates special information and advice on operating the device.

sAfety instructions

  

the warranty will expire in case of any damage caused by the failure to follow these 

operating instructions! we assume no liability for any resulting consequential damage!

 

 we assume no liability for any damage to property or personal injuries caused by 

improper use or non-compliance with the safety instructions! in such cases, the warranty 

will be null and void.

 

•   The unauthorised conversion and/or modification of the product is not permitted for safety and 

approval reasons (CE). Do not disassemble the product.

 

•   This product is not a toy. Therefore, be especially careful when children are around. 

 

  Use the product where it is out of the reach of children. 

 

•   Never use the product immediately after it has been taken from a cold room to a warm one. 

The condensation that forms can ruin the product under certain circumstances.

 

•   Avoid the following adverse conditions at the location of installation and during transport:

 

-  Extreme cold or heat, direct sunlight

 

-  Dust or flammable gases, fumes or solvents

 

-  Strong impacts, blows

 

•   Do not leave packaging material carelessly lying around, since it could become a dangerous 

plaything for children.

 

•   Handle the product with care; it can be damaged by impacts, blows, or accidental falls, even 

from a low height.

 

•   Never touch the measuring tips or a measuring point during the measuring process. There is 

the risk of an electrical shock.

 

•   Never touch areas outside of the marked handling area during a measurement.

 

•   Do not use in the immediate proximity of strong magnetic or electromagnetic fields or trans-

mission aerials. These can affect the measurement.

Version 09/15

Содержание VC-62

Страница 1: ... Symbol für leere Batterie Konformitätszeichen CE geprüft Gerät und Ausrüstung zum Arbeiten unter Spannung Persönliche Schutzmaßnahmen erforderlich Schutzklasse 2 doppelt oder verstärkte Isolierung Schutzisoliert D BEDIENUNGSANLEITUNG Spannungsprüfer VC 62 Best Nr 1313884 BestimmungsgemäSSe Verwendung Der 2polige Spannungsprüfer dient zum Messen und Anzeigen von Gleich und Wechselspannungen im ele...

Страница 2: ...ach unten Entnehmen Sie ggf die entleerten Batterien aus dem Messgerät und legen Sie zwei neue Batterien vom selben Typ siehe Technische Daten polungsrichtig in das Batteriefach ein Die Verwendung von wiederaufladbaren Akkus ist nicht zulässig Empfohlen werden Alkaline Batterien da diese eine lange Betriebszeit garantieren Schieben Sie das Batteriefach wieder nach oben bis es spürbar einrastet und...

Страница 3: ...T Symbol for empty batteries Conformity symbol CE approved Device and equipment for live works Personal protective equipment required Protection class 2 double or reinforced insulation protective insulation G OPERATING INSTRUCTIONS Voltage tester VC 62 Item no 1313884 Intended use The 2 pole voltage tester can be used to measure and display direct and alternating voltages in an electri cal low vol...

Страница 4: ...current the polarity of the voltage displays refers to the measuring tip of the measur ing instrument 3 When the batteries are empty only the warning indicator 5 for Dangerous Voltage will function when the test voltage reaches 50 V AC or 120 V DC Do not ever touch the measuring contacts if this indicator is on Replacing the batteries The voltage measured is indicated with the LEDs 7 The LED AC 9 ...

Страница 5: ...rotection 2 isolation isolation de sécurité doublées ou renforcées F MODE D EMPLOI Détecteur de tension VC 62 N de commande 1313884 Utilisation conforme Le détecteur de tension à 2 pôles est utilisé pour mesurer et afficher les tensions continues et alternatives dans les circuits électriques basse tension Le produit dispose également d un testeur de continuité acous tique et visuel L appareil fonc...

Страница 6: ...ure directe sur les prises électriques En cas de tension continue la polarité de la tension affichée se réfère à la sonde de l appareil de mesure 3 Si les piles sont déchargées seul l indicateur d avertissement 5 en cas de tension dan gereuse fonctionne à partir d une tension de détection de 50 V CA ou de 120 V CC Si cet indicateur est allumé ne touchez pas les contacts de mesure Remplacez les pil...

Страница 7: ...evens LOW BAT Symbool voor lege batterijen Conformiteitsaanduiding CE gekeurd Apparaat en uitvoering voor het werken onder spanning Persoonlijke beschermingsmaatregelen vereist Beschermklasse 2 dubbele of versterkte isolatie veiligheidsisolatie O GEBRUIKSAANWIJZING Spanningstester VC 62 Bestelnr 1313884 Beoogd gebruik De 2 polige spanningstester wordt gebruikt voor het meten en weergeven van gelij...

Страница 8: ...d Dit vereenvoudigt bijv het direct via stopcontacten meten Bij gelijkspanningen verwijst de polariteit van de weergegeven spanning naar de meetsonde van het meetinstrument 3 Bij lege batterijen werkt vanaf een testspanning van 50 V AC en 120 V DC uitsluitend de waarschuwingsindicatie 5 voor gevaarlijke spanning Raak de meetcontacten nooit aan als deze indicatie brandt Vervang de batterijen De gem...

Отзывы: