inserting / replAcing BAtteries
Disconnect the voltage tester from the respective measured object.
Hold both measuring tips together. If no signal sounds or if the LED Low Bat (12) is illuminated, the batter-
ies must be replaced.
For this purpose, loosen the screw (15) using a small Phillips head screwdriver.
Now, carefully pull the battery compartment (14) downwards along the cable.
Remove the empty batteries from the measuring instrument, where applicable, and insert new batteries of
the same type (see “Technical Data”) into the battery compartment observing the correct polarity. The use
of rechargeable batteries is not permitted. We recommend to use alkaline batteries. They guarantee a long
service life.
Slide the battery compartment back upwards until you feel it click in place and carefully close the compart-
ment with screw (15).
controls
1 Measuring probes
2 Measuring tip “-”
3 Measuring tip “+”
4 Holder for second measuring line
5 LED High Voltage
6 Beeper
7 LED for power indication
8 LED “-” polarity at main device
9 LED AC Voltage
10 LED DC Voltage
11 LED Continuity Indicator
12 LED Low Bat
13 Measuring tip light button
14 Battery compartment
15 Screw for battery compartment
functionAlity test / self-test
We recommend to test the functionality of the measuring instrument before each measurement.
Hold both measuring tips together. A signal will sound and the LED (11) turns on. The product is ready for
operation.
The measuring instrument switches on automatically when the respective measurement unit is detected.
The measurement device turns itself off automatically after every measurement procedure to save power.
If no signal sounds, replace the batteries. If functionality is not given even after replacing the batteries, the
product must not be used!
Additional self test function (all LED, TORCH, BUZZER are ON for 2 sec) is implemented for all Conrad
VTs. It can be started when VT is off. The user need to push Torch button and hold for 4 sec. After that all
LED/symbols light, Torch light and buzzer sound is active for 2 sec.
Always attach the measuring tip cover if you are no longer using the device.
VoltAge test
Connect the two measuring tips with the object to be measured.
The voltage tester automatically switches on when it detects a voltage of 6 V or higher.
When using the voltage tester in the measurement category CAT III and CAT IV, it is recommended
to attach the protective plastic covers provided to the measuring tip to decrease the length of the
free contact tips (2) and (3). This reduces the risk of a possible short cut during testing.
For ease of use, the product has a holder (4) for a second measurement line. This makes measuring
e.g. directly via mains sockets easier.
For direct current, the polarity of the voltage displays refers to the measuring tip of the measur-
ing instrument (3).
When the batteries are empty, only the warning indicator (5) for “Dangerous Voltage” will
function when the test voltage reaches 50 V/AC or 120 V/DC. Do not ever touch the measuring
contacts, if this indicator is on. Replacing the batteries.
The voltage measured is indicated with the LEDs (7).
The LED “AC” (9) is illuminated for alternating voltages and the voltage is indicated with the LEDs (7).
The LED “DC” (10) is illuminated for direct voltages and the voltage is indicated with the LEDs (7). If the
voltage has a negative polarity, the LED “-” (8) is also illuminated.
continuity test
Before a continuity check, make sure that the measurement object is de-energised.
Hold the two measuring poles on the points to be measured on the object. When current up to a maximum
of 400 kΩ +50% passes through the device, it makes a signal sound and the LED for continuity check „7“
lights up.
Disconnect the measuring tips from the measurement object after the measurement.
meAsuring point lighting
The measurement device has LED illumination on the outside of the case in order to allow measurements
when there is little light. To activate this feature press on the button (13). The LED switches off after roughly
30 seconds off to save battery power.
mAintenAnce AnD cleAning
Apart from the occasional battery change, the product is maintenance-free for you.
However, in order to ensure the accuracy of the measurement device over a long period, it is recom-
mended to have the device calibrated once a year.
Never clean the product while it is connected to a voltage source. Use a clean, dry, soft cloth for cleaning.
Do not use aggressive cleaning agents, as these can cause discolouration. Do not press too strongly on
the surface when cleaning, to prevent scratch marks.
DisposAl
a) general
Please dispose of the product, when it is no longer of use, according to the current statutory
requirements. Remove any inserted batteries and dispose of them separately from the product.
b) Batteries
You as the ultimate consumer are legally obliged (Regulation on Spent Batteries) to return all dead batter-
ies and accumulators. Disposal in the household waste is prohibited.
Contaminated rechargeable batteries are labelled with these symbols to indicate that disposal in
the domestic waste is forbidden. The symbols of the critical heavy metals are: Cd = Cadmium,
Hg = Mercury, Pb = Lead. You can return your used batteries/rechargeable batteries free of
charge to the official collection points in your municipality, in our stores, or anywhere batteries or
rechargeable batteries are sold.
technicAl DAtA
Voltage range ................................................6 - 600 V DC/AC
Frequency range ...........................................0 Hz; 16 – 400 Hz
LED resolution ...............................................+/- 6, 12, 24, 50, 120, 230, 400, 600 V
DC/AC voltage recognition ............................automatic
Auto-Power-On ..............................................> 6 V DC/AC
Response time ...............................................< 0.5 s
Max. testing current I .....................................< 3.5 mA
Battery current output ....................................max. 50 mA
Measurement category ..................................CAT III 600 V
Norms ............................................................EN 60529 und EN 61243-3:2010
Protection type ...............................................IP64
Contamination level .......................................2
Temperature range ........................................-15°C to +45 °C
Humidity ........................................................max. 85 % relative humidity, non condensing
Altitude above sea level ................................max. 2000 m
Length of measuring cables ..........................ca. 93 cm
Power supply .................................................2 x AAA / micro batteries
Weight ...........................................................130 g
Dimensions ....................................................67 x 245 x 27 mm (W x H x D)
continuity test
Indication
optic and acoustic (<400 kΩ +50%)
Test current
<5 uA
Over voltage protection
690 V DC/AC