17. TECHNICAL DATA
PPS 11810
PPS 11360
PPS 11603
Operating voltage:
100 – 240 V/AC, 50/60 Hz
Max. input current (230 V/AC, 100 V/AC):
1.2 A / 2.4 A
1.2 A / 2.5 A
1.0 A / 2.0 A
Maximum output power:
180 W
180 W
150 W
Output voltage:
1 – 18 V/DC
1 – 36 V/DC
1 – 60 V/DC
Output current:
0 – 10 A
0 – 5 A
0 – 2500 mA
Residual ripple at nominal load:
5 mV, 30 mA
Voltage control response at 10 – 100 %
load change:
50 mV
Voltage control response at mains
fluctuation (90 – 260 V/AC):
20 mV
Current control response at 10 – 90 % load
change:
100 mA
Current control response at mains
fluctuation (90 – 260 V/AC):
50 mA
Display accuracy:
±0.2% +3 dgt
OVP switch-off level of the V output:
+2 V (1 – 5 V)
+3 V (5 – 18 V)
+2 V (1 – 5 V)
+3 V (5 – 20 V)
+4 V (20 – 36 V)
+2 V (1 – 5 V)
+3 V (5 – 20 V)
+4 V (20 – 60 V)
Degree of effectiveness:
84.7 %
85.9 %
86 %
Clock signal:
100 – 120 kHz
Performance factor with active PFC:
>0.95
Device fan:
Temperature controlled (0 – 100 %)
Mains fuse slow-blow (5 x 20 mm):
F6AL250V
Operating temperature:
0 to +45 ºC
Operating humitiy:
10 – 80 %, non-condensing
Storage temperature:
-15 to +70 ºC
Storage humidity:
0 – 85 %, non-condensing
Operating altitude:
max. 2000 m above mean sea level
Safety class:
2
Approvals:
CE EMC: EN 55011, 55012, LVD: EN 60950, 61010
Weight:
2.4 kg
Dimensions (W x H x D):