21
If these two numbers do not match, please check the settings on the charger and the battery itself. It may
be that the LiPo battery has been completely discharged, or a cell may be faulty. In this case, the battery
should not be charged, as there is a risk of fire and explosion!
You can return to the previous configuration menu using the "BATT. TYPE/STOP" button.
• If the two numbers match, you can start the charging process by briefly pushing the "START/ENTER" button.
• Once the charging process has been started, various information about the
current charging progress is shown on the display.
Example:
At the upper left, the rechargeable battery type and the cell number are displayed ("LP3s" = LiPo rechargeable
battery with 3 cells); the charging current is shown in the upper middle and the current rechargeable battery voltage
at the upper right.
The lower left shows the current rechargeable battery programme ("CHG" = "CHARGE"), in the middle the elapsed
charging time and the charged capacity in mAh are displayed to the right of this.
Various information is indicated on the display during a charge/discharge process by repeatedly pressing
the button "DEC." (see chapter 19). If you do not push any button for a few seconds, the charger will return
to the normal display.
• Once the charging process has been completed, an audio signal is emitted (if it was not turned off).
If you wish to cancel the charging process, push the button "BATT. TYPE/STOP".
c) Charging Batteries with Balancer Connection ("BALANCE")
In contrast to the simple rechargeable battery programme "CHARGE" (see chapter 11. b), the rechargeable battery
programme "BALANCE" monitors the voltage of every single cell of a multiple-cell lithium rechargeable battery and
corrects it accordingly if there are any deviations.
Besides the two normal rechargeable battery connections (plus/+ and minus/-), the balancer connector for the battery
must also be connected to the charger.
The balancer connection of the rechargeable battery must be connected to the charger, e.g. via a balancer board
(enclosed in delivery content).
If you use self-customised rechargeable batteries, the balancer plug must be correctly assigned.
Example: The first pin is the minus pole of the first cell. The next connection pin is the plus pole of the
first cell; the respective next connection pin is the plus pole of the second, third, fourth, fifth and sixth cell
(depending on cell number).
The last connection pin of the balancer plug of the rechargeable battery therefore is the plus pole of the last
cell. Therefore, the same voltage can be measured between the two outer pins of the balancer plug as at
the two rechargeable battery connections directly.
Also observe that the balancer plug is always connected to the right connection that belongs to the respective channel
(1, 2 or 3).
The balancer connection that belongs to the charge/discharge channel is below the 4 mm sockets of the
respective rechargeable battery connection in each case.
The remaining procedure for charging is described in chapter 11. b).
LP3s 1.2A 12.59V