34
Capacity
Range
Resolution
Accuracy
11 nF
0.001 nF
±(5.0% + 0.1 nF)
110 nF
0.01 nF
±(5,0% + 15)
1.1 µF
0.0001 µF
11 µF
0.001 µF
±(3,0% + 10)
110 µF
0.01 µF
1.1 mF
0.0001 mF
11 mF
0.001 mF
±(10,0% + 10)
110 mF
0.01 mF
Overload protection 36 V/AC-DC
Inductance
Range
Resolution
Accuracy
Measuring frequency
11 mH
0.001 mH
±(2.0% + 0.4 mH)
ca. 1 kHz
110 mH
0.01 mH
±(5.0% + 6 mH)
11 H
0.001 H
±(5.0% + 15)
ca. 100 Hz
20 H
0.01 H
Overload protection 36 V/AC-DC
Diode test
Test voltage
Resolution
Accuracy
Test current
1.1 V
0.001 V
±(10,0% + 5)
0.3 mA (typical)
Overload protection 36 V/AC-DC
Acoustic continuity tester
<30 Ω permanent beep, test current 0.3 mA typical,
Overload protection 36 V/AC-DC
Do not exceed the maximum permitted input values. Do not contact circuits or parts of circuits if
there could be voltages higher than 25 V ACrms or 35 V DC present within them. Mortal danger!