33
13. Technical data
Display ..............................................................LCD; 11,000 counts
Measuring frequency ........................................approx. 4 measuring operations/second
Measuring cable length ....................................about 25 cm each
Automatic switch-off .........................................approx. 15 minutes
Operating voltage .............................................9 V block battery
Working conditions ...........................................0 to 50 °C (<70%rh)
Operating altitude .............................................max. 2,000 m
Storage temperature .........................................-20 °C to +60 °C (<80%rh)
Ground DMM ....................................................ca. 400 g
Dimensions (LxWxH) ........................................182 x 82 x 55 (mm)
Measurement tolerances
Statement of accuracy in ± (% of r display error in counts (= number of smallest points)). The accuracy is
valid for one year at a temperature of +23 °C ± 5 °C, and at a relative humidity of less than 70%, non-condensing.
Resistance
Range
Resolution
Accuracy
110 Ω
0.01 Ω
±(1.2% + 0.5 Ω)
1.1 kΩ
0.0001 kΩ
±(1,2% + 8)
11 kΩ
0.001 kΩ
110 kΩ
0.01 kΩ
1.1 MΩ
0.0001 MΩ
±(2,5% + 8)
11 MΩ
0.001 MΩ
110 MΩ
0.01 MΩ
Overload protection 36 V/AC-DC