VMware, Inc.
83
Appendix 14 vShield Endpoint Events and Alarms
Possible causes for events are listed in
Table 14-7
:
Table 14-7.
Possible Causes for Events
Code
Event
Possible Cause
0001
VSM_FSFD_EVENT_VERSION_MISMATCH
Compatible versions of the vShield Endpoint modules must be used. Please
refer to the vShield Endpoint Installation guide for a compatibility list.
0003
VSM_FSFD_EVENT_DISK_FULL
The vShield Endpoint Thin Agent may need to write to a file on the local
disk for file remediation purposes, as well as for temporary storage. The file
location for the temporary files is:
%SYSTEMROOT%\temp\vmware\eps010\
For remediation purposes, the needed storage is comparable to the size of
the file being remediated. It is recommended that local disks are at 95% or
less capacity. Running out of disk space may prevent vShield Endpoint from
functioning properly and from effectively protecting the affected VM.
0004
VSM_FSFD_EVENT_TIMEOUT
VM is slow to respond to SVM requests. This may happen when the VM is
temporarily running low on CPU resources.
0005
VSM_FSFD_EVENT_UNKNOWN_STATE
N/A
0006
VSM_FSFD_EVENT_MISSING_TIMER
Thin agent is not operating properly.
0007
VSM_FSFD_EVENT_TIMER_RESTORED
N/A
1000
VSM_VM_EVENT_CONNECTED
VM configured for vShield Endpoint protection will generate this event
when loaded on the corresponding ESX host, for example, during power-up
or incoming vMotion.
1001
VSM_VM_EVENT_DISCONNECTED
VM configured for vShield Endpoint protection will generate this event
when loaded on the corresponding ESX host, for example, during shutdown
or outgoing vMotion.
1002
VSM_VM_EVENT_UNKNOWN_STATE
Heavy load of event reporting on the SVM, or a communication problem
between the SVM and the vShield Manager.
N/A
VM_POWERED_OFF
N/A
2000
VSM_SVM_EVENT_ENABLED
N/A
2001
VSM_SVM_EVENT_INIT_FAILURE
vShield Endpoint SVM component failed to initialize. Please consult partner
SVM installation documentation for causes.
2003
VSM_SVM_EVENT_FSFD_FLOOD_DETECTED
The SVM is overloaded. The number of events exceeds the maximum
concurrent events threshold.
2005
VSM_SVM_EVENT_DROPPED_EVENTS
Heavy load of event reporting on the SVM, or communication problem
between the SVM and the vShield Manager.
2006
VSM_SVM_EVENT_MISSING_REPORT
1
Check SVM status.
2
Check network connection between vShield Manager and SVM.
2007
VSM_SVM_EVENT_REPORT_RESTORED
N/A
3000
VSM_HOST_EVENT_VERSION_MISMATCH
Compatible versions of the vShield Endpoint modules must be used. Please
refer to the vShield Endpoint Installation guide for a compatibility list.
3002
VSM_HOST_EVENT_UNKNOWN_STATE
Heavy load of event reporting on the SVM, or communication problem
between the SVM and the vShield Manager.
3003
VSM_HOST_EVENT_SVM_REGISTERED
N/A
3004
VSM_HOST_EVENT_SVM_UNREGISTERED
N/A
3005
VSM_HOST_EVENT_VMS_CONNECTED
N/A
3006
VSM_HOST_EVENT_VMS_DISCONNECTED
N/A
Содержание VSHIELD APP 1.0.0 UPDATE 1 - API
Страница 9: ...VMware Inc 9 vShield Manager and vShield Zones...
Страница 10: ...vShield Administration Guide 10 VMware Inc...
Страница 14: ...vShield Administration Guide 14 VMware Inc...
Страница 18: ...vShield Administration Guide 18 VMware Inc...
Страница 24: ...vShield Administration Guide 24 VMware Inc...
Страница 34: ...vShield Administration Guide 34 VMware Inc...
Страница 42: ...vShield Administration Guide 42 VMware Inc...
Страница 46: ...vShield Administration Guide 46 VMware Inc...
Страница 47: ...VMware Inc 47 vShield Edge and Port Group Isolation...
Страница 48: ...vShield Administration Guide 48 VMware Inc...
Страница 57: ...VMware Inc 57 vShield App and vShield Endpoint...
Страница 58: ...vShield Administration Guide 58 VMware Inc...
Страница 62: ...vShield Administration Guide 62 VMware Inc...
Страница 68: ...vShield Administration Guide 68 VMware Inc...
Страница 78: ...vShield Administration Guide 78 VMware Inc...
Страница 85: ...VMware Inc 85 Appendixes...
Страница 86: ...vShield Administration Guide 86 VMware Inc...
Страница 130: ...vShield Administration Guide 130 VMware Inc...
Страница 144: ...vShield Administration Guide 144 VMware Inc...