A breather and filler cap provides an opening for adding oil.
It also allows filtered air to enter the space above the oil as
the oil level goes down and allows air to leave as the oil level
goes up. It maintains constant atmospheric pressure above
the oil.
•
A sight-glass provides a direct visual indication of oil level
without opening up the reservoir.
Fill cap/breather
Suction fitting
Cleanout cover
Return line
Filter
Anti-foam
splash plate
Drain plug
Baffles
Fluid level
sight glass
Figure 15 – Hydraulic reservoir
6.4.5 Additional Recommended Features
The following features are not essential, but are recommended as
measures which will help to maximize hydraulic system reliability,
efficiency and life.
•
Magnetic drain plug(s) trap ferrous particles and should
be easily accessed for cleaning.
•
A temperature gauge, either separate or built into the
sight-glass, allows operator to read reservoir oil
temperature.
•
A strainer in the filler neck keeps large contaminants out
of the reservoir during oil addition.
•
A return line flow diffuser mounts to end of return line
drop tube and reduces the oil velocity before the oil
emerges into the main interior volume of the reservoir;
VMAC – Vehicle Mounted Air Compressors
Toll Free:
1-888-241-2289 Local: 1-250-740-3200
Fax: 1-250-740-3201
36