English
Descripcion_155
.fm - 31/1/12
VIVO-D102 Control board
39
DESCRIPTION OF THE PRODUCT
1
ELEMENTS OF THE COMPLETE INSTALLATION
Fig. 1
Elements of the complete installation
The safe and correct operation of the
installation is the responsibility of the installer.
The installation is activated by way of the fixed key
commands (6) (push button, key switch, proximity
key or magnetic key), or by way of radio transmitter.
G
8
1
Control board
2
Operator (IZAR with encoder)
3
Traffic light
4
Flashing light
5
Photocell
6
Fixed key command (push
button or key)
7
Antenna
8
Lower closing stopper
(required to programme the
run in operators with
encoder)
ELECTRICAL CABLING:
Element
Nº threads x section
Maximum length
A: Main power supply
3x1.5mm
2
30m
B: Flashing light
2x0.5mm
2
20m
C: Photocell
2x0.5mm
2
30m
D: Pushbutton or key switch
2x0.5mm
2
25m
E: Operator (motor + encoder)
Duct (2x1mm
2
+ interior screened
duct 2x0.5mm
2
)
8m (maximum 25m with cable
2x2.5mm
2
)
F: Operator release
2x0.5mm
2
25m
G: Antenna
Coaxial cable 50
k
(RG-58/U)
5m