Programacion_1
55.fm - 31/1/12
STARTING UP AND PROGRAMMING
VIVO-D102 Control board
51
Advanced Functions Programming (D1= “
A
”)
1
Press ENTER to access the programming menus. The
display lights up and D1 flashes.
2
Press the buttons ^ and
V
until D1 shows the letter
A
flashing. Press ENTER to confirm. D2 flashes.
3
Press the buttons ^ and
V
until the required D2
parameter appears. Press ENTER to confirm. D3 and
D4 flash.
4
Press the buttons ^ and
V
until the required D3 and
D4 value appears (see chart). Press ENTER to
confirm.
5
Press ESC to return to the previous display.
D1
D2
Parameter
D3
D4
Pre-
determined
option
Options or values
a
0
Flashing light
0
1
x
No pre-warning
0
2
With pre-warning
1
Garage light time
0...5.
0...9
03
03
= 3 secs;
59
= 59 secs;
2.5
= 2 min. 50 sec., etc
2
Door speed
0
1...5
03
01
: minimum speed;
05
: maximum speed
3
Slowdown speed
0
1...5
02
01
: minimum speed;
05
: maximum speed
4
Slowdown distance
0
0...5
00
00
: minimum distance;
05
: maximum
distance
5
Disabled
6
Maximum thrust
maximum thrust in opening
1...9
X
6X
1X
: minimum thrust (in opening);
9X
: maximum thrust (in opening)
maximum thrust in closing
X
1...9
X6
X1
: minimum thrust (in closing);
X9
: maximum thrust (in closing)
7
Closing
photocell
used during
standby (in automatic mode
only)
0
1
Immediate close
0
2
x
Restart standby time
0
3
Has no effect
8
Pushbutton
operation during
standby (in automatic mode
only)
0
1
Immediate close
0
2
x
Restart standby time
0
3
Has no effect
9
Opening mode
0
1
x
Opening in accordance with the mode
selected in the main functions (
F
)
0
2
Collective opening
(the control board does not obey the key
commands during opening)
0
3
Step-by-step opening
(the door halts if a key device is activated
during opening. The door closes when