![Vivo D102 Скачать руководство пользователя страница 54](http://html1.mh-extra.com/html/vivo/d102/d102_installer-manual_1039641054.webp)
Programacion_155
.fm - 31/1/12
STARTING UP AND PROGRAMMING
50
Installation Manual
Radio code programming (only with RSD) and door open/close programming (D1= “
P
”)
O
Before programming the door open/close,
ensure the turning direction of the operator is
correct (see “Prior Conditions Programming
(D1= “
C
”)” on page 49).
The radio code programming described below is
only valid if the RSD plug-in receiver has been
installed. If a different receiver is used, programme
the radio code as described in the corresponding
instructions.
1
Press ENTER to access the programming menus. The
display lights up and D1 flashes.
2
Press the buttons ^ and
V
until D1 shows the letter
P
flashing. Press ENTER to confirm. D2 flashes.
3
Press the buttons ^ and
V
until the required D2
parameter appears (see chart). Press ENTER to
confirm. D3 and D4 flash.
4.a
Radio code programming
(D2=
1
)
:
• Press the transmitter button. If the code is
correctly programmed, D3-D4 stop flashing
(remain static).
4.b
Door open/close programming
(D2=
3
)
:
• Press ENTER. D3-D4 stop flashing (remaining
static)
• Press the total opening button. D3-D4 flash
again whilst the programming of the operations
is done automatically. The door carries out the
following movements:
–
Reset (close position search)
–
Total opening
–
Total close
• When programming is finished, D3-D4 stop
flashing (remaining static).
5
Press ESC to return to the previous display.
Main Functions Programming (D1= “
F
”)
1
Press ENTER to access the programming menus. The
display lights up and D1 flashes.
2
Press the buttons ^ and
V
until D1 shows the letter
F
flashing. Press ENTER to confirm. D2 flashes.
3
Press the buttons ^ and
V
until the required D2
parameter appears. Press ENTER to confirm. D3 and
D4 flash.
4
Press the buttons ^ and
V
until the required D3 and
D4 value appears (see chart). Press ENTER to
confirm.
5
Press ESC to return to the previous display.
For operation different to the options defined in this
menu, access the advanced functions menu (see
“Advanced Functions Programming (D1= “
A
”)” on
page 51).
D1
D2
D3
D4
P
1
o
ç
Total opening radio code
programming
2
Disabled
3
o
ç
Door open/close
programming
D1
D2
Parameter
D3
D4
Pre-
determined
option
Options or values
F
1
Functioning mode
a
0
1
Automatic
0
2
x
Step-by-step
2
Standby in automatic mode
1
5
x
15 seconds
0...5.
0...9
59
= 59 sec;
2.5
= 2 min. 50 sec., etc
3
Disabled
a. For further details, see “Functioning modes” on page 41.