Page 11 of 65
3 vLoc3-DM Receiver Functions and Operations
DM Current Warning
- The vLoc3-DM locator monitors changes from the previous current reading. If the change is larger
than what is set in the user menu a warning indicator is shown in the “Info” screen.
When in the User Menu the threshold at which the warning is triggered is set by using the “Enter” key. Choosing the option
“Disabled” prevents the feature from showing the warning.
The DM Current Warning feature can be enabled or disabled using the “MyLocator3” app.
Pipe Diameter
- The vLoc3-DM receiver measures the distance to the center of the pipe. If the pipe diameter is entered the
depth indicated will be the depth to the top of the pipe, i.e., the cover depth.
To enter a pipe diameter, enter the user menu by using a long press of the info key. When in the User Menu and scroll to DM
Pipe Diameter.
Menu
Blacklight
Frequency
DM Frequency
DM Current
DM Simultaneous Info
DM Current Warning
Pipe Diameter
Medium
3Hz + 6Hz
Live
Disabled
Disabled
Use the “Enter” key to enable the diameter of the pipe to be entered.
0
+10cm
30cm
Pipe Diameter
Use the “+” and “-” keys to enter the desired value. Note that entering the incorrect value will result in a depth of cover indication
error.
The size of the incremental changes can be set using the “Enter” key.
0
+1cm
0cm
Pipe Diameter
A short press of the On/Off key sets the diameter to zero which effectively switches off the depth of cover feature and
measurements are then to the pipe center.
Exit the menu by pressing the “info” key until back to the locate screen.