Page 10 of 65
3 vLoc3-DM Receiver Functions and Operations
Sound Configuration
- Changes the sound configuration of the locate modes. Use the Enter key to select
AM
or
FM
.
•
In active locate modes:
- Frequency Modulated (
FM
) Sound pitch changes with signal strength
- Amplitude Modulated (
AM
) Sound volume changes with signal strength
•
In passive locate modes:
- Radio mode:
FM
or
Real
(Sound derived directly from the received signal)
- Power mode:
FM
or
Real
Imperial/Metric
– Use the Enter key to select Imperial or Metric measurements for the depth readings.
Continuous Info
– The locate screens can display a continuous reading of either depth, current, both or can be switched off.
Use the Enter key to select your preference.
Auto Power Off
– The unit can be set to switch off after a set time. Options are 5-minutes, 10-minutes or Never. Note that
when the accessory A-frame is connected the timer defaults to “Never.”
3.5.2
Setup - Operational
Frequency
- Press the Enter key to enter the Frequency sub-menu. Scroll up and down the table of available frequencies
using the “+” and “-” keys.
Simplify the operation of the receiver by selecting only the frequencies applicable to your
applications. To do this use the enter key to check the boxes on the right. Frequencies not checked
will not appear on the locate screen.
Frequency
1.45kHz
2.0kHz
8.01kHz
8.19kHz
8KFF
8.44kHz
9.5kHz
9.8kHz
Note also that specific frequency options have an A-frame icon next to them. It indicates that these frequencies are selected to
be used with the fault find A-frame.
DM Frequency
- Use the enter key to select either:
• 3Hz
• 4Hz
• 3+6Hz
• 4+8Hz
DM Current
- Use the enter key to select either:
Static
: - Displayed DM current is the first measurement when entering the “Info” screen.
Live
: - The displayed current is continually updated when in the “Info” screen.
DM Simultaneous Info
- Use the enter key to select either:
Enabled
: When enabled, pressing the “info” screen when the A-Frame is connected displays both the A-frame and the DM
current. Saving the info screen saves both pieces of data.
Disabled
: When disabled, pressing the “info” screen when the A-Frame is connected displays only the DM current and only the