Alarm Management
DVR User Manual
75
�
Click Start
à
Settings
à
Camera
à
Intelligent Detection
à
Tripwire to go to the following
interface.
�
Select the camera, enable the line crossing detection and set the duration.
�
Select the direction.
Direction
: A<->B, A->B and A<-B options. It is the crossing direction of the intruder who
crosses over the alert line.
A<->B
: the alarm triggers when the intruder crosses over the alert line from B to A or from A
to B.
A->B
: the alarm triggers when the intruder crosses over the alert line from A to B.
A<-B
: the alarm triggers when the intruder crosses over the alert line from B to A.
�
Draw line. Refer to the interface as shown above. Check “Draw line” and then drag the
mouse in the image to draw an alert line. Uncheck the “Draw line” when you finish the drawing.
Click the “Clear” button to delete the alert line.
�
Click “Apply” to save the settings.
�
Click “Processing Mode” to go to the alarm handling configuration interface of line
crossing detection.
Line Crossing Alarm Handling Configuration
:
�
Click Start
à
Settings
à
Alarm
à
Intelligence Alarm
à
Line Crossing to go to the following
interface.
Alarm Management
DVR User Manual
76
�
Enable or disable “Record”, “Snapshot”, “Push”, “Alarm-out”, “Preset”, “Buzzer”,
“Pop-up Video” and “E-mail”. The alarm handling setting of line crossing alarm is similar to
that of the sensor alarm (see 9.1 Sensor Alarm for details).
�
Click “Apply” to save the settings. You can click “Crossing Config” to go to the line
crossing configuration interface.
9.3.4 Intrusion Detection
Intrusion Configuration
:
Alarms will be triggered if someone or something intrudes into the pre-defined area.
�
Click Start
à
Settings
à
Camera
à
Intelligent Detection
à
Intrusion Detection to go to the
following interface.
�
Select the camera, enable the intrusion detection and set the duration.
�
Select the alarm area. Up to 4 alarm areas can be set up.
�
Draw the alarm area of the intrusion detection. Refer to the interface as shown below.
Check “Draw Area” and then click around the area where you want to set as the alarm area in
the image (the alarm area should be a closed area). Uncheck the “Draw Area” when you finish
the drawing. Click the “Clear” button to delete the alarm area.
�
Click “Apply” to save the settings.
�
Click “Processing Mode” to go to the alarm handling configuration interface of intrusion
detection.