- The grounding rod shall be inserted for at least 2/3 of its height.
- To achieve better grounding effect the following methods shall be used in the place of
grounding rod installation: cleaning of contact in the place of contact wire connection to the
ground rod, pressing of the ground, moistening of the ground using salt solution
Methods of generator connection to the route
To achieve quality in route position detection the following rules should be observed: The direct
connection of the generator to the load provides the longest tracing distance.
Several ways can be used to define the underground cable (or pipeline) route when directly
connected to the buried utility. They are as follows:
1). The ground is a return conductor
Connect the generator to one end of the cable, ground the other end of the cable
2). The cable armor is a return conductor
Connect the generator to ends of the cable; join the other ends of the cable.
3). The cable cord is a return conductor
Connect the generator to two cords from one end of the cable, join the cords from the opposite
side.