17
17
3.2. Procedure of work with the generator
SAFETY REQUIREMENTS
The dangerous voltage (from 24 to 400 V) may exist on the generator output (including the
clamps). The route detection procedure is based on the grounding of one of the generator
output clamps.
NEVER!
Touch the output connecting cables clamps and elements of the monitored buried
utility when the generator is in operation.
NEVER!
Connect and disconnect the connecting cables when the generator is in operation.
The persons properly instructed and having no medical restrictions are admitted for instrument
operation.
Personnel safe procedure for work with the generator when connecting to the route:
A.
make sure on the monitored buried utility and near it no activities are conducted or
planned which can result in deliberate or accidental touching of the current-conducting
part under voltage;
B.
make sure the generator is switched off;
C.
ground the cable conductor opposite to the generator connection point and put the
table «Grounded» («High voltage»);
D.
if the paragraphs а), c) can not be fulfilled use the contact
-free mode of connection with
inductive antenna or transmitting clamps;
5
Menu control buttons
« »
- selection of parameter to be set in the left direction by the indicator
« » - increase of value or «up» in the list
« » - reduction of value or «down» in the list
« »
- selection of parameter to be set in the right direction by the indicator
«
»-
in the «stop» condition – entering to the parameter setting / exit from parameter
setting with saving of settings
- in the «generation» condition – input of current value of output current as setup value
6
Indicator of power supply parameters
(V, hours),
work mode, generation frequency
(Hz),
set current
(А),
output parameters
(V/А/Ω/W)
7
«MATCHING»
(results)
: set current is achieved «Imatch», mode of unlimited voltage «U », maximum
voltage «Umax», power limited at the optimal level «Р lim»
8
Parameter indicated by «output multimeter»
: U «V», I «А», R «Ω» , P«W»
9
Button of selection of parameter indicated by «output multimeter»
10
Button « »«START/STOP»
of generation, matching or charging
11
Transparent window
for indication reading with closed cover
12
Plug
sealing the external power supply connector (closed)
13
Plug
sealing the output connector (opened)
14
Output connector
to connect the buried utility, transmitting antenna or “clamp”
15
Input connector
to connect
external accumulator
or
mains power supply adapter
(operation/charging)