5
5
Power supplies
Built-in battery set
Two acid-lead sealed accumulator batteries
12V/12Аh (AGM technology) with automatic
switching: 12V/24Аh or 24V/12Аh
Power resource with an ambient temperature of 0ºС depending on the initially achieved
power, minimum, hours
- continuous generation, hours
1,2
at 120W internal/180W with extra battery 12V
16
at 60W internal/15W with extra battery 12V
- pulses at single frequency, hours
3,5
at 180W internal/270W with extra battery 12V
64
at 90W internal/15W with extra battery 12V
- pulses at three frequencies, hours
2,5
at 120W internal/180W with extra battery 12V
32
at 60W internal/15W with extra battery 12V
Maximum recharge time of internal
batteries, hours
8
Power adapter for work or battery charging
Output voltage 15V, output current 15А max
Allowed external batteries
11...14V/ 20…28V ≥ 24Аh
Functional features
Automatic functions
- selection of optimum power supply mode (switching
of internal and external power sources)
- auto matching
(achieving of specified current in
the load)
- automatic
«smart» selection of output power
- special program of transmitting antenna control
- built-in automatic charger device
- automatic power cutoff when long-time idling (1min)
Automatic generation (charging) switch off
- when the batteries are discharged below limit
(prevention of deep irreversible discharge)
- when the external voltage does not match charging
mode
- when maximum allowed consumed current is
exceeded
- when the power is switch off during generation
- when there is a short-circuit during generation
- when the generation mode does not match antenna
presence/absence at the output
Type of connected loads
- direct connection to the subject with current
returning through the wire or cable armor
- direct connection to the subject with current
returning through the ground via the grounding rod
- inductive connection with the use of transmitting
framework antenna at a frequency of 8928Hz
(selected automatically when the antenna is
connected)
- inductive connection using transmitting clamps
(selection of cable from the batch is possible)
Automatic repeated matching
When there is a deviation of the specified load
current higher than ±2dB
Содержание IFL-1210