2) Contact free mode
using the inductive antenna
–
IEM -301.2 Connecting to the utility is
carried out by induction method.
To do this: remove the antenna from it package and insert active part of the antenna (pos. 16
figure 3.3) in the foundation body pos.17. Connect the antenna to the generator output
connector (pos. 14 figure 3.3) and install over assumed place of route. The antenna and route
must lay in the same plane.
3) Contact-free mode
using the
transmitting
clamp.
Allows tracing of the selected buried utilities, energized and de-energized cables. The clamp
shall be put around the conductor to be traced figure 3.4
NEVER!
Touch the clamps of connecting cables and parts of monitored buried utility
while the generator is working.
NEVER!
Mate and disconnect the connecting cables while the generator is working.
3.4 Turning on the generator power
Connect the load to the lowest connector on the generator rear panel in
accordance with the tracing procedure (pos.14 figure 3.5). The examined
route (pipeline, cable), inductive antenna or transmitting clamp can be
used as a load.
To ensure safety it is strongly recommended to complete all connection
works before the generation is started.
16
Fig.
3.3
17
Fig.
3.4
14
Fig. 3.5