3-10 Operating the DXL5000
DXL5000 User and Technical Manual
3.6 Managing Alarms
You can monitor alarms from the front panel or from the GUI on the Alarms Tab, as described in
this section.
3.6.1
Interpreting the Front Panel LEDs
The following figure and table describes how to interpret the LEDs on the front panel.
The LEDs on the front panel alert you to alarm conditions for the DXL5000.
The following table describes how to interpret the front panel alarms.
TX POWER
LCD display
Indicates the current transmitter output power level in dBm.
RSL dBm
LCD display
Indicates the current receiver signal power level in dBm.
MAJOR ALARM
LED
•
Green
=No alarm detected.
•
Red
=Indicates a major problem; a flashing light indicates that service is lost.
MINOR ALARM
LED
•
Green
=No alarm detected.
•
Amber
=Indicates an alert relay has been triggered; a minor problem exists
but service is not lost.
SCM STATUS
LED
•
Dark
=No alarm detected.
•
Amber
=Indicates a minor SCM problem exists but service is not lost.
•
Red
=Indicates a major SCM problem exists causing the system to lose
service.
RSL dBm
TX POWER
ALARM LEDs