3-8 Operating the DXL5000
DXL5000 User and Technical Manual
3.3.5
Determining Optimal System Utilization
Referring to the figure in
Setup–Modulator (Transmitter) and Demodulator
on page 3-6, your system throughput (
Sys TP
) is calculated by the values
that you specify in the
Symbol Rate
and
Modulation
fields.
Use the following table to determine the maximum allowed symbol rate to match the allowed
channel bandwidth. For example, if you choose a
Symbol Rate
of
20.5
and a modulation of
16QAM
,
Sys TP
shows
74.83
Mbps
.
For optimal performance, utilization should not exceed 100%; if it does, the number turns red to
indicate an overload that you should correct. You can use the following formula to calculate the
utilization of the DXL5000:
Utilization %
= total of the 4
Data Rates
I
Sys TP
x 100
Carefully select the
Symbol Rate
,
Modulation
scheme and required transmission
Data Rate
s.
For example, if you have a
Sys TP
of 40 Mbps and choose a
Data Rate
of 20 Mbps for the type
of input in
Core Channel 1
, the
Utilization %
displays 50%, meaning that you can add another
channel as long as the combined data rates do not cause the
Utilization %
to exceed 98%.
SMPTE BNC-3
19.392658
(fixed)
(No additional parameters.)
T1 RJ45-1
,
T1 RJ45-2
1.544
(fixed)
LBO
:
–30
or
–36
Channel Coding
:
Enabled
(B8ZS) or
Disabled
(AMI)
E1 RJ45-1
,
E1 RJ45-2
2.048
(fixed)
LBO
:
–12
or
–43
Channel Coding
:
Enabled
(HDB3) or
Disabled
(AMI)
Ethernet RJ45-1
0.064
—
90.0
Mode
:
10 Mb/s
,
100 Mb/s
, or
Auto
Duplex
:
Full
or
Half
RS232
,
RS485
(Data rate and
Baud rate must
match)
600
,
1200
,
2400
,
4800
,
9600
,
19200
,
28822
,
38600
,
52600
,
115200
,
230400
Baud Rate
:
600
,
1200
,
2400
,
4800
,
9600
,
19200
,
28822
,
38600
,
52600
,
115200
,
230400
Channel
Bandwidth
(MHz)
Maximum
Symbol Rate
(Msps)
Maximum Net Data Rate (Mbps)
for Each Modulation Scheme
(Sys TP)
QPSK
16QAM
32QAM
64QAM
10
8.2
15.01
29.93
37.39
44.94
12
9.8
17.93
35.77
44.69
53.70
17
13.9
25.44
50.74
63.38
76.17
19
15.6
28.55
56.94
71.14
85.49
20
16.4
30.01
59.86
74.78
89.87
25
20.5
37.52
74.83
93.48
112.34
30
24.6
45.02
89.79
112.18
134.81
40
32.8
60.02
119.72
149.57
179.74
Data I/O
Data Rate
Additional Parameters
Содержание DXL5000 RX
Страница 1: ...User and Technical Manual DXL5000 Digital Microwave System Manual Part No 400571 1 Rev B March 2010 ...
Страница 18: ...2 8 Installing the DXL5000 DXL5000 User and Technical Manual ...
Страница 32: ...3 14 Operating the DXL5000 DXL5000 User and Technical Manual ...
Страница 36: ...A 4 DXL5000 Specifications DXL5000 User and Technical Manual ...
Страница 40: ...Index 4 DXL5000 User and Technical Manual ...