AXS-10
Single-Door Access Control System – Installation Guide
Page 2 of 8
DE6270_V10
3. Installation
3.1 Controller Unit Installation
Figure 3 - Control Unit Installation
3.2 Proximity Reader Installation
Caution: Do not install the RDR-3 on a metal surface or on a
metal door frame, since this decreases the key reading range
significantly. If you have to install the reader on a metal surface,
use a spacer plate so that the reader will be at least 1 cm (3/8 in.)
away from the metal. You may use RDR-BACK which is an
optional spacer plate made specifically for this purpose.
When installing two readers, you may install them in close
proximity to each other.
Figure 4 - Proximity Reader Installation
3.3 Setting DIP Switch
Figure 5 - DIP Switch Setting
4. Wiring
4.1 Electromagnetic Strike Wiring
Electro-Magnetic Locks Powered by AXS-10
A. Connecting Electro-magnetic
lock that opens the door
when power is supplied
B. Connecting Electro-magnetic
lock that opens the door
when power is disconnected
Electro-Magnetic Locks Powered by an External Power Supply
C. Connecting Electro-magnetic
lock that opens the door
when power is supplied
D. Connecting Electro-magnetic
lock that opens the door
when power is disconnected