Insert duration time

 

(seconds).

 

Example: For 35 seconds, press “10” three times

 and press “1” five times (the display will show 35).

Present master key

 

to save the unlock time

.

 

Press 

MODE

 

several times until

 

 SPECIAL LED lights and “UL” is displayed.

Enter

 

installer password

 (or factory defined installer

 password F1, F2, F3, F1, F2, F3). The ADD LED start flashing.

 

Setting Door Unlock Duration

 

Press 

Mode

 

Erasing all User Keys by Installer

Present master key

 to the internal 

reader, until the display blanks out and the yellow 

LED lights constantly and then remove the key

 

Press

 

Mode

 

several times until SPECIAL

LED  starts blinking and “Er” is displayed.

 

Enter

installer password

 

(or factory defined installer 

password F1, F2, F3, F1, F2, F3). The green ADD LED flashes.

 

Press

 

Mode

Note: A master user key should be assigned before erasing user keys

Note: The ERASE ALL function does NOT erase the master key

Present master key

 until ADD LED flashes.

 

Press

 

Mode

 

twice until SPECIAL LED lights

 

Present master key

 

to the internal reader, until the display 

blanks out and yellow LED lights constantly and then remove the key

 

Type

 

4 step password

Verify that “Er” is displayed.

 

Erasing All User Keys by the User

Press

 

Mode

 

Present tag

 

(until the SPECIAL LED stops flashing)

 

Press

 

MODE

 

several times until

 

“SO”

 is displayed

 

Enter

 

installer password

 

(or factory defined installer

 

password F1, F2, F3, F1, F2, F3). The ADD LED flashes.

 

Master Key Programming

Press

 

Mode

(Refer to the installation instructions document, par. 5.5)

 

replacing Installer Password

/

Setting

Present master key

 

until ADD LED flashes.

Enter 4-step

 

user password

 (factory 

default F3, F3, F3, F3). The display shows “Er”

 

Press

 

Mode

several times until SPECIAL LED lights

replacing User Password

/

Setting

Press

 

Mode

Press

 

Mode

several times until display shows “PP”

Enter new user

  

4-step password

Present master key

 

until the green

 and yellow LEDs light (to confirm the password).

 

Present master key

 

until ADD LED flashes

.

Present master key

 

or press “MODE” to confirm, until 

 

the number  disappears and 

 

red LED flashes

 

Press 

Mode

The DELETE LED starts flashing - 

indicating that the system is ready to delete a key.

 

Present key

to internal

reader .The key number will

 

be displayed  momentarily, 

 

the display blank and the

 

red LED will flash

 

Enter key number

Press combination of 100/10/1 buttons

 (the key number you wish to delete)

 

Deleting User Key

Press

 

Mode

Present a key

The key  number is displayed for few seconds 

and then the green LED starts to flash (ready for adding next key).

 

 

Present master key

 

until ADD LED flashes.

 

ding User Key

Ad

 

Press

 

Mode

 

Содержание AXS-10

Страница 1: ...ioner The AXS 10 kit includes AXS 10 controller RDR 3 proximity reader with 1m 3 ft 5 wire cable Installation instructions User guide Control unit base template for wall installation Additional tools and equipment that may be needed Proximity tags or cards ordered separately Power supply for the controller 12V AC DC Electromagnetic strike EMS unit RTE request to exit push button or PIR if required...

Страница 2: ...ch is an optional spacer plate made specifically for this purpose When installing two readers you may install them in close proximity to each other Figure 4 Proximity Reader Installation 3 3 Setting DIP Switch Figure 5 DIP Switch Setting 4 Wiring 4 1 Electromagnetic Strike Wiring Electro Magnetic Locks Powered by AXS 10 A Connecting Electro magnetic lock that opens the door when power is supplied ...

Страница 3: ... Figure 7 Connecting One Proximity Reader Figure 8 Connecting Two Proximity Readers Figure 9 DIP Switch Setting for Proximity or Magnetic Reader 4 4 Magnetic Stripe Readers Wiring Figure 10 Magnetic Stripe Reader RDC 3 Wiring Figure 11 Magnetic Stripe Reader RDC 3MP Wiring Reader 1 Data In terminal for RDC 3 and RDC 3MP is used for clock signal Figure 12 Magnetic Stripe Reader RDC 3MP Wiring ...

Страница 4: ...ation Figure 12 AXS 10 network without PC Figure 13 AXS 10 Network with PC 5 Programming IMPORTANT When using the magnetic reader RDC 3 3M 3P the internal proximity reader is disabled In such a case all procedures in which the internal reader is involved should be performed with the external magnetic card reader Note While the system is in one of the programming modes the AXS 10 does not operate t...

Страница 5: ...inue without saving the new unlock duration 5 5 Entering Exiting Toggle Mode To turn the AXS 10 into Toggle mode Setting the Unlock Duration see par 5 4 to 100 seconds turns the AXS 10 into Toggle mode If the unlock time setting is less then 100 second the AXS 10 is in regular mode To turn the AXS 10 from Toggle mode into Regular mode Set the unlock duration to any number other than 100 Then exit ...

Страница 6: ...liability of VT VT shall not under any circumstances whatsoever be liable for any inaccuracy error of judgment default or negligence of VT its employees officers agents or any other party or of the purchaser or user arising from any assistance or communication of any kind regarding the configuration design installation or creation of security system involving the Product that being the responsibil...

Страница 7: ...layed Erasing All User Keys by the User Press Mode Present tag until the SPECIAL LED stops flashing Press MODE several times until SO is displayed Enter installer password or factory defined installer password F1 F2 F3 F1 F2 F3 The ADD LED flashes Master Key Programming Press Mode Refer to the installation instructions document par 5 5 replacing Installer Password Setting Present master key until ...

Страница 8: ...Page 8 of 8 DE6270_V10 APPENDIX B AXS 10 Controller Mounting Template ...

Отзывы: