LOCK MODES
A maximum of two users can exist in a lock. A lock can operate in either
Single Mode
or
Dual Custody Mode
.
Note:
For a UL listed installation, only one user can be activated.
•
Single Mode
E
Single Mode
defaults to having only a
Manager User
(User 1) in the lock. A
second
user
(User 2)
can then be added by the Manager User (User 1).
(See section on
Manager User Operations
.)
In Single Mode only one valid user combination is required to open the lock - the Manager
User (User 1) combination or the User 2 combination.
Note:
Default lock status from the factory is Single Mode with an opening
combination of “50 25 50” for the Manager User (User 1).
•
Dual Custody Mode
E
E
Dual Custody Mode
defaults to two users in the lock -
User 1
and
User 2
.
Both user combinations are required to open the lock - the User 1 combination and the
User 2 combination.
Note:
Manager User Operations are not available in Dual Custody Mode.
LOCK OPERATING CONVENTIONS
•
The LC Series lock models are battery powered (PowerSaver
TM
Technology.)
• To
clear
a combination or keystroke, press the
¸
¸
¸
¸
¸
key.
• If the bolt is not retracted within 4-6 seconds after a valid opening combination is
accepted, the lock will “relock”.
•
Slide Bolt (Auto Locking) Technology:
Once a combination has been entered and
accepted, the lock bolt movement works in conjunction with the bolt works of the
container. When the bolt works are disengaged to open the container, the lock bolt will
slide into the “unlocked” or retracted position. Once the bolt works are extended to the
locked position, the lock bolt automatically slides into the “locked” position. The lock will
not open if force is applied to the end or side of the bolt.
LC SERIES
O
PERATING
I
NSTRUCTIONS
M
ODELS
LCLX, LCMX, TLCL, TLCM
Document Number 3032.034 Rev. B - 03/05
Содержание LCLX
Страница 7: ...NOTES...