41: Configuring data usage monitor
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
© Virtual Access 2018
GW6600 Series User manual
Issue: 1.7
Page 464 of 519
Figure 220: The data usage configuration page
Web Field/UCI/Package Option
Description
Web: Enabled
UCI: procrustes.@limit[0].enabled
Opt: enabled
Enable data usage monitor on this interface group.
0
Disabled.
1
Enabled.
Web: Billing Start
UCI:
procrustes.@limit[0].billing_period_start_
day
Opt: billing_period_start_day
Day of month on which the billing period starts.
1
Range
1 – 28
Web: Interfaces
UCI: procrustes.@limit[0].interfaces
Opt: interfaces
Monitor and apply limits to these interfaces as a group. Configure
multiple interfaces via UCI using a space separator.
Example:
uci set procrustes.@limit[0].interfaces=”lan wan”
Web: Monthly Limit (MB)
UCI:
procrustes..@limit[0].monthly_data_limit
Opt: monthly_data_limit
Defines monthly data traffic limit in megabytes (MB). This is total
RX and TX on the interface.
0
Zero means no limit.
Range
Web: Monthly Warnings (MB)
UCI:
procrustes.@limit[0].monthly_warning_le
vels
Opt: monthly_warning_levels
Defines data usage limits for generating a log message and a VA
event alert when used traffic reaches specified levels. Levels are
specified in MB.
Set multiple limits via UCI using a space separator.
Example:
uci set procrustes.@limit[0].monthly_warning_levels=”15
25”
0
Zero means no limit.
Range
Table 170: Information table for data usage commands