INSTRUCTION FOR USE
ENGLISH
16
DP1
DP2
CHARGING CURVE
ON
OFF
IUIa-ACD for Lead-acid (Wet)batteries
OFF
OFF
IUIa-GEL for Gel batteries of Exide-Sonnenschein
OFF
ON
IUU0-GEL for HAZE Gel and AGM batteries of other manufacturers
ON
ON
IUIUa-AGM for Discover AGM batteries
Battery charging
Fully charge the batteries (see the procedure in Maintenance chapter).
Battery discharge
When the batteries pattern is full (G, Figure 8), the batteries allow the machine to work normally. When the batteries pattern is low (H,
Figure 8), the batteries must be charged. A few seconds after the low battery pattern shows, the brush/pad-holder is automatically turned
off, while the drive system stays on. Drive the machine to the appointed recharging area immediately.
CAUTION!
When the batteries are discharged, charge them as soon as possible, as that condition makes their life shorter.
Check for battery charge at least once a week.
Figure 8
AGM
0000.H
G
AGM
0000.H
H