Manual VIPA Accessories
Chapter 4 Deployment
HB37E - IM - RE_306-1LE00 - Rev. 09/28
4-3
Depending on the used Siemens S5 rack the power supply happens via
backplane bus or via the front supply.
Attention!
Please only supply the module via the front-side if there is no supply by
backplane bus.
Simultaneous infeed should absolutely be avoided.
The configuration happens as hardware configuration in the Profibus DP
master engineering tool by assigning the IM 306 DP slave module.
VIPA serves GSD files for the IM 306 DP slave. These may be downloaded
from the "Service area" of www.vipa.de. The IM 306 DP slave may be
configured as DP-V0 or as DP-V1 slave. There is a GSD file for each type.
The assignment to the slave type is shown at the following table:
Slave type
GSD file
DP-V0 VI100BB4.GSD
DP-V1 VI110BB4.GSD
By installing the corresponding GSD file the IM 306 DP slave is listed as
"VIPA 306-1LE00 (DPVx) at:
Profibus-DP > Additional Field Devices > I/O > VIPA_306_1XX00
•
Install your Profibus system.
•
Start your project engineering tool with a new project.
•
Configure a master system with a Profibus subnet.
•
For the project engineering of the IM 306 DP-Slave choose the
corresponding "VIPA 306-1LE00 (DPVx)" from the hardware catalog,
according to the functionality you want, and pull it to the DP master
subnet.
•
Enter at properties of the DP slave a Profibus address between 2 and
125 and set the same address at the address switch. Please regard with
VIPA system dependent the Profibus address 1 is reserved.
•
Parameterize the DP slave. More information may be found at "DP-Vx
slave parameterization".
•
Open the configuration table by clicking to the placed DP slave. Starting
with the 1. slot insert every module of the Siemens S5 rack with the
plugged sequence from the hardware catalog. For each 115U module
enter the "slot" number and for each 135U/155U module the rack
"periphery address", respectively if not available in the hardware catalog
insert a corresponding "substitution" module.
•
Safe and transfer your project to the PLC.
At the following pages these points of the fast introduction are more
described.
Power supply
Configuration
GSD file
Proceeding
Содержание IM 306-1LE00
Страница 2: ......
Страница 6: ...Contents Manual VIPA Accessories ii HB37E IM RE_306 1LE00 Rev 09 28...
Страница 34: ...Chapter 3 Hardware description Manual VIPA Accessories 3 6 HB37E IM RE_306 1LE00 Rev 09 28...
Страница 58: ...Index Manual VIPA Accessories A 2 HB37E IM RE_306 1LE00 Rev 09 28 M Stich...