Chapter 4 Deployment
Manual VIPA Accessories
4-2
HB37E - IM - RE_306-1LE00 - Rev. 09/28
Fast introduction
•
The module 306-1LE00 may only be used at the IM slot of the AG-115U.
Here the module is to be connected via Profibus to a master system.
•
In the rack besides the IM 306 DP slave at the IM slot only digital
respectively analog modules are allowed.
•
Due to the data transfer via Profibus maximally 244byte of input data
and 244byte of output data may be transferred.
•
The interrupt capability is only supported by deployment of the module
with order number 306-1LZ00.
CPU
IM
IM
IM
CP
IM 306-1LE00
P W
E R
RD
DE
64
32
16
8
4
2
1
-
1
0
PW
ER
RD
DE
64
32
16
8
4
2
1
-
1
0
Master system
CPU
CP
I/O
I/O
I/O
I/O
CC
CC
EU
EU
EU
EU
IM 306-1LE00
IM 306-1LE00
PW
ER
RD
DE
64
32
16
8
4
2
1
-
1
0
•
Isolate the AG from the supply voltage.
•
With exception of the digital and analog modules remove every module
from the rack.
•
Plug at the IM slot an adaption module casing, by hanging it up at the
upper edge, turning it downward and snapping it to the rack. So that you
can plug the adaption module casing, you have to remove the separator
located at the top on the right-side of the rack.
•
Fix the adaption module casing with its screws.
•
Plug the IM 306-1LE00 DP slave to the adaption module casing by
snapping the module to the backplane bus by means of the left guide
track.
•
Preset the Profibus address via the DIP switch at the front. This address
must be identical to the Profibus address you have preset during
hardware configuration.
In principle is valid
Installation