Chapter 5 Deployment Command interface
Manual VIPA System 300V
5-18
HB130E - CP - RE_343-2AH10 - Rev. 08/41
Meaning of the Flags
Flag
Meaning
OFFLINE_READY
The flag is set when the online phase is active.
APF
The flag is set when the voltage on the AS-i
cable is too low.
NORMAL_MODE
The flag is set when the CP is in the normal
mode.
CONFIG_MODE
The flag is set in the
configuration mode
and
reset in the
protected mode.
AUTO_ADDR_AVAIL
The flag is set when automatic address
programming is possible (in other words,
exactly one AS-i slave is currently out of
operation).
AUTO_ADDR_ASSIGN
The flag is set when the automatic address
programming is possible (in other words
AUTO_ADDR_ENABLE = 1
and
there is no
"incorrect" slave connected to the AS-i
Interface).
LDS_0
The flag is set when an AS-i slave exists with
address 0.
CONFIG_OK
The flag is set when desired (configured) and
actual configuration match.
OFFLINE
The flag is set when the mode is changed to
OFFLINE or this mode has already been
adopted.
EPROM_OK
The flag is set when the test of the internal
Flash-ROM did not detect any errors.
AUTO_ADDR_ENABLE
The flag indicates whether the automatic
address programming is enabled (BIT=0) or
disabled (BIT=1) by the user.
INTERNAL
The flag is always set.
PERIPHERY_FAULT
The flag is set when at least one AS-i slave is
signaling a peripheral fault.
MPO startup
The flag "master_power_on_startup" flag is set
after the power supply of the AS-i slave master
has been turned on. If the master is later
changed to OFFLINE, the bit is reset.