No. of stop bits, 1 or 2.
Available formats:
7N1, 7N2, 7O1, 7O2, 7E1, 7E2, 8N1, 8N2, 8O1, 8O2, 8E1, 8E2,
Protocol description
ZDA - Time & Date - UTC, Day, Month, Year and Local Time Zone
1 2 3 4 5 6 7
| | | | | | |
$--ZDA,hhmmss.ss,xx,xx,xxxx,xx,xx*hh<CR><LF>
Field Number:
1) Universal Time Coordinated (UTC)
2) Day, 01 to 31
3) Month, 01 to 12
4) Year
5) Local zone description, 00 to +- 13 hours
6) Local zone minutes description, same sign as local hours
7) Checksum