Protocol 16*
STC HH MM SS DD MO MO YY HL HL ML ML ECT
Code description
Hex value
STC
Start Transmission Character 02
H
Ten UTC hours
30-32
H
Unit UTC hours
30-39
M
Ten UTC minutes
30-35
M
Unit UTC minutes
30-39
S
Ten UTC seconds
30-35
S
Unit UTC seconds
30-39
D
Ten date UTC
30-33
D
Unit date UTC
30-39
MO
Ten month UTC
30-31
MO
Unit month UTC
30-39
Y
Ten year UTC
30-39
Y
Unit year UTC
30-39
HL
Ten LT hours
30-32
HL
Unit LT hours
30-39
ML
Ten LT minutes
30-35
ML
Unit LT minutes
30-39
ECT
End transmission character
03
* Protocol 16M = Message transmitted each minute.