MARINE MASTER CLOCK
Document: 1717en19.doc
Author: PM
User Manual
Date: 2017-12-22
Page: 30 of 51
WESTERSTRAND URFABRIK AB
P.O. Box 133
Tel. +46 506 48000
Internet:: http://www.westerstrand.se
SE-545 23 TÖREBODA
Fax. +46 506 48051
E-mail:
Status
With this function each input/output status can be checked.
Example:
Check the status of the synchronisation source receiver.
Select function using
↓
.
Accept with YES.
Press NO until wished function is shown.
Accept with YES.
Press NO until wished input/output is shown.
Accept with YES.
The Master Clock has accepted 60% of the synchronisation messages.
Last reception was 14/10 19:59:00.
Return to running mode press
←
.
←
←
MON 26 SEP 2016
U10:11:35 L12:11
SPEC.-FUNCTIONS
SPEC.-FUNCTIONS
STATUS
STATUS
SYNC.SOURCE
MON 26 SEP 2016
U10:11:35 L12:11
NMEA RS485 60%
14OCT 19:59:00
STATUS
SYNC.SOURCE
SPEC.-FUNCTIONS
STATUS
SPEC.-FUNCTIONS
Содержание 3005050028
Страница 1: ...TECHNICAL MANUAL MASTER CLOCK SYSTEM TECHNICAL USER MANUAL A100K10807 ...
Страница 76: ......
Страница 78: ......