WESTERSTRAND
Document: 9539en14.doc
Author: PM
Date: 2018-08-15
Page: 2 av 5
WESTERSTRAND URFABRIK AB
Box 133
Tel. 0506 48000
Internet:: http://www.westerstrand.se
545 23 TÖREBODA
Fax. 0506 48051
E-mail:
Outputs for slave movements *:
Control clocks:
Analogue display, with background illumination.
Output 1:
Impulse system:
1/1 minute, 1/2 minute, second, 1/2 second, time code (TC)
Type of time:
LT, UTC
Impulse length:
Minute 0.1-9.9 sec.
Second 0.1-1 sec.
Output 2:
Impulse system:
1/1 minute, 1/2 minute, second, 1/2 second, time code (TC)
Type of time:
LT, UTC
Impulse length:
Minute 0.1-9.9 sec.
Second 0.1-1 sec.
Output 3:
Impulse system:
1/1 minute, 1/2 minute, second, 1/2 second, time code (TC)
Type of time:
LT, UTC
Impulse length:
Minute 0.1-9.9 sec.
Second 0.1-1 sec.
Output 4:
Impulse system:
2-wire, 1/1 minute, 1/2 minute, second, 1/2 second, time code (TC).
3-wire for forward forward/back. 1/1-minute alt. 1/2-minute.
Type of time:
LT, UTC
Impulse length:
Minute 0.1-9.9 sec.
Second 0.1-1 sec.
Max. load / output:
2A
Total load all
outputs together:
2.5A
The outputs have short circuit protection that is restored automatically.
*Analogue intelligent slave clocks connected to time code output receive the time code and steps to correct time
by rapid impulses. The rapid impulses have a speed of approx. 10 steps /second. To step forward 11 hours takes
approx. 1 minute and 10 seconds.