5) INTENDED AND IMPROPER USES OF THE ST AIRLIFT
5.1) Intended uses
The Mod.
V64/74
stairlift is a system for transporting one person
SEATED ON A WHEELCHAIR OR ON
A SPECIAL SEAT (optional)
with
STRAIGHT
rail at
CONSTANT
gradient which can be installed on stairs
having the following characteristics:
- Ambient:
Indoor and outdoor
- Steps:
Parallel
- Gradient:
Minimum 0° - Maximum 50°
User characteristics: Self-sufficient, physically and mentally suitable, familiar with the equipment’s
operation and the use and maintenance instructions.
WARNING: If the person using the system is not self-sufficient, the stairlift must be operated
by another person acting as attendant. While the lift is in motion, sit still and do not move or rock.
5.2) Improper uses
- Transporting objects on the platform
- Overloading the stairlift (e.g., disabled person with electric wheelchair having total weight in excess
of the maximum permitted load. See section 4, Technical Specifications).
- Use of the stairlift by unauthorised persons (e.g. children, people who do not meet the requirements
specified in point 5.1)
Improper uses
Problems
Use on stairs having gradient
greater than 50°:
Overheating of motor
User standing on platform:
Risk of falling
Operation by unsuitable operator:
Risk of falling
Transporting more than one person:
Risk of falling and of overheating of motor
WARNING: DO NOT MAKE MODIFICATIONS INTENDED FOR ANY USE, DO NOT INSERT EXTRA-
NEOUS OBJECTS OR LIQUIDS IN HOLES OR CRACKS, DO NOT SPRAY LIQUIDS ONTO THE STAIRLIFT
6.1) Preliminary checks
Checks to be made before the lift is put into service.
Skill level: OS - Specialist operator appointed by the manufacturer.
ORGANO CONTROLLATO
RISULTATO DEL CONTROLLO
ITEM CHECKED
RESULT OF CHECK
Controls:
Correct operation in response to controls.
Correct timing of the start-up controls.
Efficiency of emergency stop.
Safety devices:
Check that the safety device is tripped, stopping the lift.
- Sensor edges
- Electric limit switches
- Over-run safety device
- Anti-crushing platform base
Power supply:
Mains voltage and frequency as specified in point 6.2.
Earth connection:
Check that the lift system’s earth line is connected to the earth
line of the mains system.
6) PREPARATION FOR COMMISSIONING
7512131
Содержание V 64
Страница 44: ...44 SAFETY BARS ...
Страница 47: ...47 RETRACTABLE SAFETY BARS ...
Страница 50: ...50 GUARDS ONLY FOR MOD V64 ONLY FOR MOD V74 ...
Страница 52: ...52 6 9 8 7 10 4 2 1 7 7 1 2 11 13 12 1 2 5 3 RAIL ...
Страница 54: ...54 14 5 8 9 2 3 11 6 10 13 4 1 7 12 2 15 ELECTRICAL PANEL B I ...
Страница 58: ...58 1 2 3 4 FOOTREST GUARD BOARD DRIVE CABLES INDEPENDENT BARS RETRACTABLE BARS ...
Страница 60: ...60 2 4 1 3 5 6 CONTROL BOARDS ...
Страница 62: ...62 ...
Страница 63: ...63 ...
Страница 64: ...64 ...