20
L=
7511131
PLATFORM
WIDTH
A (new) = A (table) +
measured raiser - 170
tan (alpha)
A (new) = A (table) -
170 - measured raiser
tan (alpha)
A + tot steps - D
cos (alpha)
If the first raiser measured is lower than 170 mm:
“A” values are calculated considering the first raiser
of 170 mm.
If the first raiser measure is very different from the
theoretic value used for the calculations (170 mm),
the “A” value must be recalculated according to the
following formula:
If the first raiser measured is higher than 170 mm:
This table can be only used with alpha angle higher
than 20 degrees. Below 20°, it is necessary to carry
out a special study according to the type of staircase.
In case of angles lower than 20°, please contact Vimec
to receive soon the rail installation data.
7512131