3
RS16.P
EN
3.1 Description of output function
0-1
Accessories power supply:
Permanent 24 V DC output.
0-11
Blinking:
24 Vdc output powered when the gate is moving.
0-17
Photo-test or gate open warning light:
24 V DC output for signalling gate status or performing the safety test:
With DIP 8 = OFF it is Gate Open Warning Light
- Not powered with gate closed
- Powered continuously with gate open or moving
With DIP 8 = ON it is Photo-test
Used for the power supply of the transmitters of the safety devices.
Note:
Using the photo-test requires specific wiring of the safety devices (par. 4.3).
3.2 Description of input function
51
Step by step (N.O.)
:
Sequential command input, to control the complete travel of the gate. It works with the following cycle: open-stop-close-stop or open-stop-
close-open according to the setting of DIP 3
52
Pedestrian (N.O.):
Command input for opening to the pedestrian distance.
61
Stop (N.C.):
Gate stops, does not turn off automatic closing.
If not used, jumper with the common (99)
62
Photocell when closing - PHC (N.C.):
Photocell when closing, with the gate stationary it allows opening, when opening it does not trigger, with the gate open it does not allow
closing and on release it resets the automatic closing time, when closing it commands immediate reopening.
If not used, jumper with the common (99)
63
Photocell - PH (N.C.):
Functions according to the DIP 6 setting.
DIP 6 = OFF: photocell, active both when closing and when opening, with the gate stationary it does not allow opening, during opening it
stops the movement and on release it continues opening, with the gate open it does not allow closing and on release it resets the automatic
closing time, when closing it stops the movement and on release it commands reopening.
DIP 6 = ON: safety sensitive edge, N.C. dry contact, with the gate stationary it does not allow opening, when opening it disengages, with
the gate open it does not allow closing and on release it resets the automatic closing time, when closing it disengages.
If not used, jumper with the common (99).
4 Connecting accessories
4.1 Key switch and control devices
EDS1
Step by step
Pedestrian
COM
COM
N.O.
N.O.
N.C. N.C.
99
61
63
62
52
51
PED
COM
P.
P.
COM
N.O.
COM
N.O.
N.C. N.C.
52 51 62
99
63 64 61
PED
COM
P.
P.