4.4 Sensitive edge

51 52

99

62 63 61

BAR

CO

M

4.5 Stop push button

52 51 62

99

63 64 61

ST

OP

CO

M

5 Changing the programmable parameters

APERTURA

APERTURA

The control panel is programmed by default with the following parameters:

- automatic closing:  

30 s

- opening direction:   

to the right

- pedestrian opening position:  1 m

Notes:

Do not change the wiring for the electric motors. To reverse the opening direction, follow the procedure described below in paragraph 5.2.

The control panel never needs travel setting as this is automatically measured with each action. When the card is started a full open-close action is per-

formed to calibrate the travel (it takes place at slower speed as the control panel does not know the exact position of the gate).

To change the default settings, follow the instructions provided below.

NOTES: to change the programmable parameters, the gate must be stationary.

WARNING! THE SAFETY DEVICES ARE DISABLED WHILE THE PROGRAMMABLE PARAMETERS ARE BEING CHANGED.

5.1 Changing the automatic closing time

1.   While the gate is stationary, press and hold PRG for 2 s; the flashing light comes on and remains steadily lit to indicate that programming is in progress. 

The gate closes and reopens.

2.   When the gate reaches its opening stop limit, once the desired reclosing time has elapsed (120 s max), press 51 (the gate closes again).

OPENING

Содержание RS16.P

Страница 1: ...Installer manual RS16 P 24 Vdc control unit for sliding gate ACTO 404D...

Страница 2: ...xample of installation 1 3 Description of the terminal blocks 2 4 Connecting accessories 3 5 Changing the programmable parameters 5 6 Trimmer functions 6 7 Functions of the buttons 6 8 DIP switch func...

Страница 3: ...power supply 24 Vdc Maximum motor power 80 W Output for flashing light 24 Vdc 10 W max Accessories power supply 24 Vdc 300 mA Receiver memory 50 remote controls Receiver frequency 433 MHz Remote contr...

Страница 4: ...PHC PHO STP 51 52 62 63 61 99 17 0 11 1 0 24V 24V 24V BLINK SCA C N N F L L N 230 Vac 120 Vac 12 Vdc 1 3Ah 12 Vdc 1 3Ah B B B B R 7 8 ANT _ ANT _ M F1 5x20 T 1 6A B B A A C D D STOP COM ON 1 2 3 4 5 6...

Страница 5: ...closing PHC N C Photocell when closing with the gate stationary it allows opening when opening it does not trigger with the gate open it does not allow closing and on release it resets the automatic c...

Страница 6: ...act when the photocells are not engaged the PHC LED must be on if not used then jumper between COM and PHC you must observe the polarity of the power supply for the photocells 4 3 Photocells and photo...

Страница 7: ...card is started a full open close action is per formed to calibrate the travel it takes place at slower speed as the control panel does not know the exact position of the gate To change the default se...

Страница 8: ...5 6 7 8 MRX PWR 51 PRG MRX AN AN ON 1 2 3 4 5 6 7 PWR 51 PRG MRX 8 DIP switch functions ON 1 2 3 4 5 6 7 8 PWR 51 ANT _ ANT _ ON 1 2 3 4 5 6 7 8 PWR 51 ANT _ ANT _ ON 1 2 3 4 5 6 7 8 A Dip Function S...

Страница 9: ...push button Signal MRX LED Description 1 MRX Off Press and hold down the MRX push button for no more than 7 s 2 MRX remote control With the MRX push button still pressed press the button of the remote...

Страница 10: ...least one remote control or add an external receiver maximum capacity 50 remote controls As soon as the gate starts it stops and reverses Motor torque not sufficient Increase the power with the trimme...

Страница 11: ...in which it is to be incorporated has been declared in conformity when applicable with the provisions of Directive 2006 42 EC He declares that the relevant technical documentation has been constitute...

Страница 12: ...Viale Vicenza 14 36063 Marostica VI Italy www vimar com RS16 P installer EN 00 1804...

Отзывы: